Connections:
RF Connection:
The RF-output is located at the rear of the unit. The nominal output level is 30dBmV to
50dBmV. The output connector is 75Ω F-female connector.
The test point in the unit's rear panel is for monitoring the RF output signal. This test point is attenuated -20dB
below RF input signal. The test point connector is 75Ω F-female connector.
Optical Connection:
The fiber output is equipped with SC/APC or FC/APC connector. When installing the
fiber, do not exceed minimum bending radius. For the best operation maintain all optical connector as clean
as possible, use NCM-Isopropyl Alcohol or other high purity isopropyl alcohol. Dry the surfaces using dry
compressed air.
Installation Instructions
1-
Use 4 screws to attach the receiver OR-200 to 19” rack mounting.
2-
Connect the RF coax into RF output(F-type) on the rear panel.
3-
Clean and dry all optical connectors.
4-
Plug the optical connector into Optical Input on the rear panel.(
Do not look into this connector
when laser is operating. The laser can cause serious eye damage.)
5-
Connect the AC power cord into the power jack and ground GND both on the rear panel of NCM-
OR-200. With the Power Key off, wait until RF LED and PD LED (on front panel) blinks. Display
shows:
-The Key is closed
Please, Turn it on
6-
Turn power key on. Permit the system to load. Please wait and do not turn the power key off until
monitor system starts. The NCM-OR-200 will show the following displays:
->The Key is on ...
Please Wait : 5 Seg.