Model 7815 Parcel Bench Scale User’s Manual
16
Step-by-step Instructions
for RE-CAL Mode
Follow these steps to re-configure your scale
(without weights). Refer to Figure 2.
1. From the normal weighing mode, press SW-
1…
DIAG
is displayed.
2. Press the
ZERO
key until…
RE-CAL
is displayed.
3. Press the
TEST
key…
150.1
is displayed. (Displays the current
capacity/resolution setting)
4. Press the
ZERO
key until desired capacity/
resolution is displayed.
5. Press the
TEST
key to select a new capacity/
resolution. If the scale is operating in LB
mode…
The unit will display
CLASS
.
6. Press the
ZERO
key to toggle between
SCALE
and
CLASS
.
7. When the choice you want is displayed,
press the
TEST
key…
DONE
is displayed.
8. Press the
TEST
key or SW-1 to return to
normal weighing mode.
Re-Calibration Mode
The re-calibration (RE-CAL) mode menu lets you
change the scale resolution or rounding method
without using any calibration weights. If you want
to change the unit of measure operation, you
must perform a full calibration using test weights.
For a scale originally calibrated in the lb. mode,
you may also change rounding methods (i.e.,
scale or classifier).