Getting Started….QUICKLY! 

 

It is now time to configure the Mirror Module for use in your 
application.  The process is pretty easy.  You will need to con

figure the Mirror Module so that it knows how many control

lers you want to talk to, the model of the relay controller, and 
a few other simple parameters.  Follow these simple steps... 
 
Step 9: 

After a few moments, the following screen (shown below) will 
appear.  The settings shown represent part of our initial test

ing.  Every user will have to create custom settings based on 
the devices they are using.  In this section we will identify all of 
the elements of the configuration screen and provide you with 
a brief overview of their function.  Many of the default settings 
do not need to be changed.  The number of devices you are 
controlling and the serial numbers will be different for every 
user. 

This setting tells the ZigBee Mirror Module how many devices you want to 
communicate with.  Most users will probably only use the ZigBee Mirror 
Module with ONE remote device.  However, as your application grows, Zig

Bee Mirror Modules are capable of talking to 24 different remote relay con

trollers.  Make sure this setting matches the number of remote relay control

lers EXACTLY. 

Step 9:  You may see a few failed attempts during initial communications.  
This is normal.  However, you should verify the PGM/RUN Jumper is set to 
PGM on the ZigBee Mirror Module.  Once the jumper is set, make sure 
power is applied and the READY light is lit.  Make sure the controller is 
powered down when changing the jumper, the Microprocessor on the 
ZigBee Mirror Module reads the jumper setting on Power

Up ONLY. 

Serial numbers are a very important part of using ZigBee Mirror Modules.  
You may notice we do not require you to enter the entire serial number.  The 
“base” serial number is the first part of the serial number, and is shared by 
all devices.  You should never change the “base” serial number unless you 
want to broadcast Mirror data to ALL devices.  For most applications, leave 
this setting as it is. 

2

Way Communication vs. 2

Wau XR Port Confirmation is a very impor

tant topic that will be discussed in depth in Step 10 on the next page.  

The Debounce Setting controls the 
Reaction Time between an input 
change and a “Trigger” to activate 
a remote relay.  Lower settings 
make the ZigBee Mirror Module 
more Sensitive while larger set

tings offer better noise immunity.  
Most users will want to use a 
value of 0. 

Advanced Features will be discussed 
in a later portion of the manual.  
These features are not required for 
most applications. 

Configure the Refresh Setting to 1 
for most applications.  Other set

tings will be discussed later in the 
manual. 

You can suspend communications 
to any remote device by making it 
inactive.  By default, all should be 
active (“Yes” in every row). 

Enter the Lat 8 Digits of the Serial 
Number of EACH remote Relay 
Controller in this field.  To use this 
field, click on the serial number.  A 
Box will appear that allows you to 
make changes.  Make necessary 
changes for your relay controllers.  
Move your mouse to exit and save 
your edited changes.  If the box 
turns RED after editing, there is an 
error in the data you have en

tered.  Please verify the serial 
number and try again.  Only 8 
digits are allowed, each Digit is 
character from 0

9 and A

F. 

You MUST tell the Mirror Module the type of controller 
you are using by clicking on the Arrow buttons on each 
side.  This controls the command set the Mirror Module 
sends to the remote relay controller.  These settings must 
be 100% accurate for correct communications. 

These Settings Cannot be Changed. 

Input Assignment will be discussed in 
Step 11 on the next page. 

This help box will provide you with 
useful hints as you move your mouse to 
different elements of the user interface. 

Use this button if you would like for 
us to manufacture many ZigBee 
Mirror Modules with the exact same 
settings. 

Read the Current Settings stored in 
the ZigBee Mirror Module. 

Store the Current Settings in the 
ZigBee Mirror Module. 

Содержание ZigBee ZSCAN16 MIRROR

Страница 1: ...gBee Mirror Modules allow you to remotely control wireless relays without the use of a computer and without the need for any program ming skills 2 Way communication allows you to review the status of...

Страница 2: ...l over a re mote relay controller Behavior may be unpredictable if you attempt to control a remote relay controller with a computer and a ZigBee Mirror Module at the same time For best results you sho...

Страница 3: ...uter Step 2 Now the driver software is installed we need to open the de vice manager to see what COM port is assigned to the modem If you are using Windows XP Pro Click on the Start Menu and select Co...

Страница 4: ...le Record the type of Controller and the Last 8 Digits of the Serial Number DO NOT MIX UP THE ZIGBEE MODULES Reinstall the ZigBee module on the controller it came from making sure all pins are properl...

Страница 5: ...se serial number unless you want to broadcast Mirror data to ALL devices For most applications leave this setting as it is 2 Way Communication vs 2 Wau XR Port Confirmation is a very impor tant topic...

Страница 6: ...s may want to connect a push button to any available input to manually trigger a Refresh condition When power returns to the remote relay controller the relay will automatically update to the current...

Страница 7: ...igning Devices and Serial Numbers to the Configuration Software This will Make the Most Efficient Use of your Inputs All 8 Inputs talk to Device Number 1 Device Number 1 top of page is a ProXR 8 Chann...

Страница 8: ...in the firmware of this device at this time Testing of this device was a very important part of the development of this ZigBee Mirror Module Most tests included a ZigBee 32 Channel Relay Controller 2...

Страница 9: ...mended Calculated Mapping Bytes By Default the ZigBee Mirror software will calculate the MAP Byte which determines the starting input location for every controller Most users will want to keep the de...

Страница 10: ...8 Contact Closure Input Bank 2 Input 7 Ground Bank 2 Input 7 Contact Closure Input Bank 2 Input 6 Ground Bank 2 Input 6 Contact Closure Input Bank 2 Input 5 Ground Bank 2 Input 5 Contact Closure Input...

Страница 11: ...ikey com and www mouser com that could work with some minor drilling We do not recommend any particular part number Users should review enclosure types carefully Metal enclosures should not be used un...

Страница 12: ...if the product has been altered or damaged Copyrights and Trademarks Copyright 2009 by NCD All rights reserved Other brand and product names are trademarks of registered trademarks of their respectiv...

Отзывы: