Device Characteristics 

 

Voltage Requirements: 

10

15VDC Regulated or Automotive Supply Recommended 

UNREGULATED WALL ADAPTERS SHOULD NOT BE USED WITH 
THIS DEVICE. 
 

Amperage Requirements:  

300MA Absolute MAX 

 

Power Connector type:

 2.1mm 

Center 

Positive 

 

Power Supply:

 

   

PWR12

 (www.iorelay.com) 

Power Cable:

 

   CP

2185

ND (www.digikey.com) 

 

 

   CP

2189

ND (www.digikey.com) 

Power Connector:   

SC1052

ND (www.digikey.com) 

 

Input Ratings: 

The inputs of the ZigBee Mirror Module were designed to ac

cept contact closures ONLY.  Voltages should not be applied to 
the inputs.  All inputs are pulled up to 5VDC using a 1K Resis

tor.  All inputs share a single common ground. 
 

Input Compatibility: 

Switches 
Push Buttons 
Magnetic Reed Switches 
Mechanical Relays 
Motion Detectors (if equipped with contact closure outputs) 
Any other device that can connect 2 wires together 
 

Transmission Range: 

Up to 300 Feet using XBee Module. 
Up to 1 Mile using XBee Pro module and Rooftop Antenna. 
Communication range will vary greatly and is very difficult to 
predict.  For best results, choose a controller with an external 
antenna.  This allows for positioning the antenna for better 
communication.  The most popular ZigBee choice is the XBee 
Pro Module with the External Antenna (this is the most expen

sive option when ordering).  This device offers the best possi

ble range and flexibility if you determine an outdoor antenna 
may be required. 
 

Enclosures: 

ZigBee Mirror Modules were not profiled for use with a specific 
enclosure.  Many enclosures are available from 
www.digikey.com and www.mouser.com that could work with 
some minor drilling.  We do not recommend any particular 
part number.  Users should review enclosure types carefully.  
Metal enclosures should not be used unless you have chosen 
the External Antenna Option and you plan to mount the an

tenna outside the enclosure. 
 
 
 
 
 

Operating/Storage Temperature:

   

40 to +125° C 

 
Note: Temperature ratings are based on Ratings provided to us 
by the manufacturer of the components used in our products.  
This rating represents the most temperature sensitive compo

nent used.  We do not do any form of environmental testing to 
verify manufacturer ratings. 
 

Country of Origin: 

This device was designed and manufactured in the United 
States of America using components from many countries. 
 

FCC/UL Approvals: 

NCD Implements communication technologies from 
www.digi.com.  ZigBee communication devices are UL/FCC 
approved for use in the United States and Europe.  Agency ap

provals may not be available in all countries.  Details on agency 
approvals are available from www.digi.com.  It is the policy of 
National Control Devices to assist customers in UL/FCC compli

ance in any way necessary, including design modifications, if 
required, to meet UL/FCC compliance.  NCD does not directly 
obtain approval from these agencies as product volumes are 
too low to be practical for all NCD devices.  To date, many NCD 
devices have met these approvals without design modifica

tions, when installed in a proper enclosure that meets certifica

tion requirements.  Electrically, no design changes have ever 
been required to meet these certifications. 
 

Technical Support: 

Please 

contact National Control Devices

 if you are seeking 

technical support for this or other devices. 

Содержание ZigBee ZSCAN16 MIRROR

Страница 1: ...gBee Mirror Modules allow you to remotely control wireless relays without the use of a computer and without the need for any program ming skills 2 Way communication allows you to review the status of...

Страница 2: ...l over a re mote relay controller Behavior may be unpredictable if you attempt to control a remote relay controller with a computer and a ZigBee Mirror Module at the same time For best results you sho...

Страница 3: ...uter Step 2 Now the driver software is installed we need to open the de vice manager to see what COM port is assigned to the modem If you are using Windows XP Pro Click on the Start Menu and select Co...

Страница 4: ...le Record the type of Controller and the Last 8 Digits of the Serial Number DO NOT MIX UP THE ZIGBEE MODULES Reinstall the ZigBee module on the controller it came from making sure all pins are properl...

Страница 5: ...se serial number unless you want to broadcast Mirror data to ALL devices For most applications leave this setting as it is 2 Way Communication vs 2 Wau XR Port Confirmation is a very impor tant topic...

Страница 6: ...s may want to connect a push button to any available input to manually trigger a Refresh condition When power returns to the remote relay controller the relay will automatically update to the current...

Страница 7: ...igning Devices and Serial Numbers to the Configuration Software This will Make the Most Efficient Use of your Inputs All 8 Inputs talk to Device Number 1 Device Number 1 top of page is a ProXR 8 Chann...

Страница 8: ...in the firmware of this device at this time Testing of this device was a very important part of the development of this ZigBee Mirror Module Most tests included a ZigBee 32 Channel Relay Controller 2...

Страница 9: ...mended Calculated Mapping Bytes By Default the ZigBee Mirror software will calculate the MAP Byte which determines the starting input location for every controller Most users will want to keep the de...

Страница 10: ...8 Contact Closure Input Bank 2 Input 7 Ground Bank 2 Input 7 Contact Closure Input Bank 2 Input 6 Ground Bank 2 Input 6 Contact Closure Input Bank 2 Input 5 Ground Bank 2 Input 5 Contact Closure Input...

Страница 11: ...ikey com and www mouser com that could work with some minor drilling We do not recommend any particular part number Users should review enclosure types carefully Metal enclosures should not be used un...

Страница 12: ...if the product has been altered or damaged Copyrights and Trademarks Copyright 2009 by NCD All rights reserved Other brand and product names are trademarks of registered trademarks of their respectiv...

Отзывы: