Changing Baud Rates
Change the USART Baud Rate
Send the Following Bytes via RS-485:
9600 Baud USART: F3, 00, 25, 80
19,200 Baud USART: F3, 00, 4B, 00
38,400 Baud USART: F3, 00, 96, 00
57,600 Baud USART: F3, 00, E1, 00
115,200 Baud USART: F3, 01, C2, 00 (Experimental, Not recommended as there may be communications
problems)
Read USART Baud Rate: 245 (Three Bytes will be Returned Indicating the Baud Rate)
9,600: 00 25 80
19,200: 00 4B 00
38,400: 00 96 00
57,600: 00 E1 00
115,200: 01 C2 00
Change the RS-485 Baud Rate
Send the Following Bytes via RS-485
9600 Baud USART: F4, 00, 25, 80
19,200 Baud USART: F4, 00, 4B, 00
38,400 Baud USART: F4, 00, 96, 00
57,600 Baud USART: F4, 00, E1, 00
115,200 Baud USART: F4, 01, C2, 00 (Experimental, Not recommended as there may be communications
problems)
Read USART Baud Rate: 246 (Three Bytes will be Returned Indicating the Baud Rate)
9,600: 00 25 80
19,200: 00 4B 00
38,400: 00 96 00
Содержание RS-485