RS-485 Serial Settings – Emulator
The following commands are used to control the speed and stop bits of the RS-485 bus.
Get Stop Bits:
7E 00 10 10 00 00 00 00 00 00 00 FF FF FF FE 00 00 F7 0D F0
Response:
7E 00 11 90 00 13 A2 00 41 8C 58 B6 FF FE C2 7C 01 00 00 00 A3
Set Stop Bits:
7E 00 11 10 00 00 00 00 00 00 00 FF FF FF FE 00 00 F7 06 01 F9
Response:
7E 00 1C 90 00 13 A2 00 41 8C 58 B6 FF FE C2 7C 00 00 00 00 00 00 FF 00 00 00 00 00 00 00 00 A5
Get Baud Rate:
7E 00 10 10 00 00 00 00 00 00 00 FF FF FF FE 00 00 F7 0B F2
Response:
7E 00 11 90 00 13 A2 00 41 8C 58 B6 FF FE C2 7C 00 25 80 00 FF
Set Baud Rate:
7E 00 13 10 00 00 00 00 00 00 00 FF FF FF FE 00 00 F7 01 00 25 80 57
Response:
7E 00 1C 90 00 13 A2 00 41 8C 58 B6 FF FE C2 7C 00 00 00 00 00 00 FF 00 00 00 00 00 00 00 00 A5
Command Errors – Emulator
Should there be any errors in issuing commands, the following response will be returned:
7E 00 11 90 00 13 A2 00 41 8C 58 B6 FF FE C2 7D 01 00 00 00 A2
Factory Reset
This should be done only when absolutely necessary. To reset the module, follow these steps in order:
1.
Power-down the module.
2.
Install the C And BR jumpers.
3.
Power-up the module.
4.
Module will Reset the USART to 57.6k Baud
5.
Module will Reset the RS485 Port to 9600 Baud
6.
Power-down the module.
7.
Remove the C And BR Jumpers
8.
Power-Up the module and use default settings.
Note: If the bus length exceeds more than 5,000 feet, users may experience data corruption.
This factory reset
process is true only for the Emulator and Autoencoder Version.