G
EN
3
E
THERNET W
/N-B
UTTON
Push Notification Quick Start Guide
N a t i o n a l C o n t r o l D e v i c e s
Страница 1: ...GEN3 ETHERNET W N BUTTON Push Notification Quick Start Guide National Control Devices...
Страница 2: ...ware will then send a text or email from the computer to your selected recipients All the Features You Need Send SMS or Email Message Compatible with ANY Contact Closure Sensor Dry Contact no voltage...
Страница 3: ...module directly to the Ethernet port of your PC When configuring settings in this way you will need to leave the static IP address jumper in place alter the settings select Apply Settings power down t...
Страница 4: ...oard Select Discovered Network Devices button then click on the IP Address this will open your browser and show you the Web Interface Connection and all its features By selecting the Discovered Networ...
Страница 5: ...t support DHCP simply power the board down and install a jumper on the pins directly to the left of the Ethernet Jack then power the board back up This will force the module to use a static IP address...
Страница 6: ...nored If you intend to enter Static IP address settings make sure this box is NOT checked IP Address This setting is only applicable if Use DHCP is unchecked This field configures the Static IP addres...
Страница 7: ...ld configures the Port the module should attempt to establish a connection to on start up Local Port This field is only applicable when Socket Type is set to TCP Server This field configures the Port...
Страница 8: ...efault password for the web interface is admin If desired you may change this password using the Password Setting Fields After the new password is set it will take effect after the next power cycle Fa...
Страница 9: ...Button Communicating to the Board 1 Download and install the version of N Button Pro or N Button Lite that you purchased with the board Open N Button Then Click Device Manager You must add the board...
Страница 10: ...le click the IP Address and the IP Address and Mac Address will populate the Network area above TCP UDP Port Keep default setting for TCP Port 2101 and UDP Port 3333 TCP Connection Check the TCP Conne...
Страница 11: ...ch input on the board 1 Click the Scan Channel Button to open Properties Name Create a name Device The one you created Bank ID It will be 1 Channel ID The input you are reading with this widget Style...
Страница 12: ...hen the dry contact circuit is closed You can now create a Scan Channel Widget for each of the inputs on the board then setup the automation to send the text and or email Testing Inputs Using a dry co...
Страница 13: ...lick New in the Automation Manager Window to open the Rule Type Window Click Push Notification Contact Closure Rule 1 Select Settings under Push Notification Contact Closure to select the device you c...
Страница 14: ...Under Action Type select Send Email You can also set a message for other actions such as when the contact closure opens to send a message when the circuit opens This will notify you wen the closure h...
Страница 15: ...ith a comma Add your Subject and message Click OK in all open windows and return to the desktop 2 After finishing all previous page settings all recipients will receive an email once the contact closu...
Страница 16: ...tton on the side of the Ethernet module for 5 seconds to reset the module back to factory settings 3 Use the NCD5500 Configuration Software for Windows to discover the device o Make sure that the IP a...
Страница 17: ...e the NCD5500 Configuration Software for Windows to discover the device o Make sure that the IP address dropdown box in the top left of the NCD5500 Configuration software is set to your computer s ext...
Страница 18: ...iscussions are welcome on applications and you are encouraged to share your experiences with other users Visit the community here community ncd io Serial Port Tool Questions for configuring N Button S...