BTR-S
ERIES
O
PERATION
& M
AINTENANCE
M
ANUAL
12838 Stainless Drive, Holland, MI 49424
Phone: 616/399-5600 Fax 616/399-3084
Copyright 2018 BRAWN Mixer
www.BRAWNMIXER.com
Page 8 of 9
11/27/2018
TABLE 3: RECOMMENDED LUBRICANTS
Ambient
Temperature (F)
Formulation
Oil
Manufacturer
Oil Brand Name
20° to 104°
Mineral
Texaco
Meropa 220
20° to 104°
Mineral
Shell
Omala EP 220
Ambient
Temperature (F)
Formulation
Oil
Manufacturer
Oil Brand Name
14° to 176°
Synthetic
Texaco
Pinnacle EP680
14° to 176°
Synthetic
Shell
Omala HD 680
-13° to 140°
Synthetic
Texaco
Pinnacle EP220
-13° to 140°
Synthetic
Shell
Omala HD 220
-40° to 50°
Synthetic
Texaco
Pinnacle EP32
-40° to 50°
Synthetic
Shell
Omala HD 32
20° to 104°
Food Grade
Chevron
FM ISO 220
20° to 104°
Synthetic Food Grade
OilJAX
Magnaplate 85W140-FG
5° to 125°
Fluid Grease
Mobil
Mobilux EP023
-30° to 140°
Synthetic Fluid Grease
Mobil
Mobilith SHC 007
-30° to 140°
Synthetic Fluid Grease
Shell
Tivela Compound A
Ambient
Temperature (F)
Formulation
Grease
Manufacturer
Grease Brand Name
-20° to 140°
Mineral
Texaco
Multifak EP2
-20° to 140°
Mineral
Shell
Cypernia RA/C3
Ambient
Temperature (F)
Formulation
Grease
Manufacturer
Grease Brand Name
-58° to 230°
Synthetic
Texaco
Starfak 2202
-58° to 230°
Synthetic
Shell
Aero Shell
5° to 230°
Food Grade
Lubriplate
SIF 1
STANDARD OIL - ISO VG220
OPTIONAL LUBRICANTS
STANDARD BREARING GREASE - NL GI 2EP lithium
OPTIONAL BEARING GREASE
STORAGE
Units shipped from Brawn Mixer are intended to be used within 30 days after receipt and presumed to be stored indoors in
a heated building. Store mixers as packaged by the factory. If you intend storing units under adverse conditions or for a
long period of time, special storage precautions will be necessary.
1. Store in a sheltered area away from chemical vapors or steam.
2. Cover.
3. Do not store in sunlight or near high heat.
4. Spray oil on exposed shafts and seals. Remove oil on start-up.
5. Rotate output shaft 360º every 3-4 weeks.
6. Mixers should not be stored near vibrating machinery to avoid damage to the bearings.
7. If electric motors have been subjected to humid conditions, check the insulation resistance between phase and mass
and between the different phases. The resistance should not be less than 100 megohms. If the resistance is less,
please consult the facto