The default configurations of the ports are illustrated in Figure 5 below:
Figure 5: Default settings for the two port types of the NH 210
DIP Switch settings for the 10/100 UTP ports:
Duplex
AutoNeg
Rate
UP
Full
Auto
10
DOWN
Half
Manual
100
Power Connection
Connect the power cord to the switch and to an active AC outlet. A built-in
power supply automatically adjusts to any outlet providing between 90 VAC
and 264 VAC at 50/60 Hz.
For a 115 Volt configuration, use minimum type SJT (SVT) 18/3 power cord,
rated 250 Volts AC, 10 Amps, with a maximum length of 15 feet. Terminate
one end in an IEC 320 attachment plug, the other in a NEMA 5-15P plug.
The power cord to be used with a 230 Volt configuration is minimum type
SJT (SVT) 18/3, rated 250 Volts AC, 10 Amps with a maximum length of 15
feet. One end is terminated in an IEC 320 attachment plug. The other end is
8