background image

GEN4065 4000 Surge Watts/3250 Running Watts Portable Generator  

18  

 

STOPPING THE GENERATOR 

 

To stop this generator: 
1. Turn off all connected electrical devices and then unplug them. 

2. Switch the circuit breaker to the “OFF” position. 

3. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator. 

4. Set the engine switch to the “OFF” position. 

5. Turn the fuel valve to the “OFF” position. 
 

                                                                                

   

Allow this generator to cool down before touching areas that become hot during operation. 
 
                                                                                

 

Allowing gasoline to sit in this generator's fuel tank for extended time without use can increase the difficulty in starting this generator in 

the future. Never store this generator for extended time with gasoline in the fuel tank. 
 

 

MAINTENANCE/CARE 

 

Proper routine maintenance of this generator is essential for safe, economical, and trouble-free operation. It will help prolong the life of this generator 

as well as help reduce air pollution. Perform maintenance checks and procedures according to the schedule in Figure 7. 
 

 
                                                                                

 

Never perform maintenance procedures while this generator is running. Allow this generator to cool before commencing any maintenance 
procedures. Keep heat, sparks and flame away.
 
 

                                                                                

 

Improper maintenance and/or failure to correct any problems prior to operating this generator can cause a malfunction which could cause 

death or serious injury. Always follow the inspection and maintenance recommendations and schedules in this manual. 
 

Recommended Maintenance Schedule 

 

 

 

Each Use 

Every Month or 
Each 20 Hrs 

Every 3 Months or 
Each 50 Hrs 

Every 6 Months or 
Each 100 Hrs 

Every Year or 
Each 300 Hrs 

Engine Oil 

Check Level 

 

 

 

 

 Replace  

X (first use) 

 

 

Air Filter 

Check 

 

 

 

 

 Clean     

 

 

Fuel Filler Cap 

Clean 

 

 

 

 

Spark Plug 

Check/Clean 

 

 

 

 

Fuel Tank 

Verify Gas Level 

 

 

 

 

 Clean      

  

Figure 7 - Recommended maintenance schedule 

 

 

Cleaning the Generator 

 

Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, 

vacuum and/or pressurized air. 
 

Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion. 

 

Never use gasoline to clean parts of this generator. 
 

 

Meijer.com

Содержание GEN4065

Страница 1: ...that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN TH...

Страница 2: ...ts 3250 Running Watts Portable Generator FEATURES 4 Stroke OHV Engine Recoil Start 6 5 HP Gasoline Engine Automatic Low Oil Shutdown 2 120 Volt A C Outlets 1 12 Volt D C Outlet 4 Gallon Fuel Tank Engi...

Страница 3: ...contiguous states excluding the states with high altitude areas identified in 40 CFR part 1068 Appendix III To exercise this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free...

Страница 4: ...ons you do not understand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or deat...

Страница 5: ...SECURE THE GENERATOR WITH A CHAIN OR ROPE AS THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY Keep at least several feet of clearance on all sides to allow proper ventilation for this generator Che...

Страница 6: ...least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Use this...

Страница 7: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 7 Meijer com...

Страница 8: ...65 4000 Surge Watts 3250 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator Meijer...

Страница 9: ...able Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETA...

Страница 10: ...nd controls of this generator 9 AC Circuit Fuse 10 AC Circuit Fuse 11 120 Volt AC Output Socket 12 120 Volt AC Output Socket 13 12 Volt DC Output Socket 14 DC Circuit Fuse 1 Fuel Tank Cap 2 Control Pa...

Страница 11: ...nkcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 fluid oz 0 59 L for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator Add the...

Страница 12: ...ecause gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN4065 Fuel Tank Capacity...

Страница 13: ...vel currently in the fuel tank If necessary add fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of...

Страница 14: ...sized cord can overheat short out and cause a fire Usage Do not use fuel stabilizers with this generator doing so could cause damage to the generator or decrease the fuel and operating efficiency of t...

Страница 15: ...total wattage of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less t...

Страница 16: ...lt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 4000 do not attempt to draw more than 3500 Watts from the 120 Volt outlet Draws high...

Страница 17: ...enerator Failing to use the correct procedure can cause a battery to explode seriously injuring anyone nearby Keep heat sparks flame and smoking materials away from the battery To connect 12 Volt batt...

Страница 18: ...ocedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat...

Страница 19: ...ery 100 hours of use time The oil capacity for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator engine is 20 fluid oz 0 6 L To drain the oil from this generator It is necessar...

Страница 20: ...and install a new spark plug A F6TC spark plug such as NGK BPR5ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 028 0 031in 0 7 0 8mm See Figure 9 5 If re usin...

Страница 21: ...trouble persists call our customer help line at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time Symptom Cause Solution Engine switch is set to off Set engine switch to on Fuel valve is turned to c...

Страница 22: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 22 GEN4065 4000 SURGE WATTS 3250 RUNNING WATTS PORTABLE GENERATOR PARTS DIAGRAM Meijer com...

Страница 23: ...som 2 17 Bolt GB T5789 M6 12 8 18 Tank Cock 1 19 Fuel Pipe 1 20 Muffler Guard Cover 1 21 Bolt GB T5789 M6 16 2 22 Muffler 1 23 Bolt GB T16674 M8 20 3 24 Muffler Bracket 1 25 Nut GB T6184 M8 12 26 Engi...

Страница 24: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 24 GEN4065 2011 08 Meijer com...

Отзывы: