background image

GEN4065 4000 Surge Watts/3250 Running Watts Portable Generator  

14  

 

STARTING THE GENERATOR 

 

STOP!

 

Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been 
correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for 

customer service. 

 

                                                                                 

 

Usage:

 Consult a physician(s) before using this generator if using a pacemaker. Electromagnetic fields in close proximity to a heart 

pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter. 
 
                                                                               

 

Usage:

 Prolonged exposure to high noise levels can be hazardous to hearing. Always wear ANSI-approved hearing protection when 

operating or working around the generator when it is running. 
 

                                                                               

 

Usage:

 This generator is not intended to power sensitive electronic equipment such as TVs, DVD players, stereos, desktop 

computers or laptop computers without the use of an appropriate line conditioner and/or surge protector (both not included). 

Sensitive electronic equipment should be operated on approved inverter type generators or pure sine wave generators. For additional 

information consult the devices operation manual or call customer service at 1-866-460-9436 Monday - Friday, 8 AM - 4 PM Central Time. 
 

                                                                                 

 

Usage:

 Avoid the use of extension cords if possible. If you choose to use them, be sure they are sized adequately to handle the flow of 

electricity. An undersized cord can overheat, short out and cause a fire. 
 
                                                                               

 

Usage:

  Do not use fuel stabilizers with this generator, doing so could cause damage to the generator, or decrease the fuel and operating 

efficiency of the generator.  You may choose to add a fuel conditioner to oxygenate the fuel to help it run more efficiently. 
 
                                                                                

  

Disconnect all electrical loads from this generator before attempting to start. 
 

To start this generator: 
1. Confirm that there are no electrical devices connected to this generator. Connected devices may increase the difficulty in starting the engine. 

2. Confirm that this generator is properly grounded. (See “Ground the Generator” section of this manual.) 

3. Turn the fuel valve to the “on” position. 

4. Move the choke lever to the “closed” position. 

5. Set the engine switch to the “on” position. 

6. Slowly pull on the recoil starter handle, shown in Figure 4, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the 

cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back. 

7. If the engine fails to start, repeat step 6. NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting 

again. If problems persist, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time. 

8. Once the engine has started and runs for about a minute, move the choke lever approximately half way towards the “open” position. Wait an 

additional 30 seconds and then move the choke lever completely over to the “open” position. 

9. Allow this generator to run for several minutes before connecting any electrical devices. 
 
 

 

 

 

Figure 4 

The Recoil Start is located on the left side of 

the generator. 

Meijer.com

Содержание GEN4065

Страница 1: ...that may occur We reserve the right to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN TH...

Страница 2: ...ts 3250 Running Watts Portable Generator FEATURES 4 Stroke OHV Engine Recoil Start 6 5 HP Gasoline Engine Automatic Low Oil Shutdown 2 120 Volt A C Outlets 1 12 Volt D C Outlet 4 Gallon Fuel Tank Engi...

Страница 3: ...contiguous states excluding the states with high altitude areas identified in 40 CFR part 1068 Appendix III To exercise this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free...

Страница 4: ...ons you do not understand This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or deat...

Страница 5: ...SECURE THE GENERATOR WITH A CHAIN OR ROPE AS THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY Keep at least several feet of clearance on all sides to allow proper ventilation for this generator Che...

Страница 6: ...least several feet of clearance on all sides of this generator during operation Do not enclose this generator in any structure Usage Misuse of this generator can damage it or shorten its life Use this...

Страница 7: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 7 Meijer com...

Страница 8: ...65 4000 Surge Watts 3250 Running Watts Portable Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator Meijer...

Страница 9: ...able Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETA...

Страница 10: ...nd controls of this generator 9 AC Circuit Fuse 10 AC Circuit Fuse 11 120 Volt AC Output Socket 12 120 Volt AC Output Socket 13 12 Volt DC Output Socket 14 DC Circuit Fuse 1 Fuel Tank Cap 2 Control Pa...

Страница 11: ...nkcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 20 fluid oz 0 59 L for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator Add the...

Страница 12: ...ecause gasoline can expand do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Model GEN4065 Fuel Tank Capacity...

Страница 13: ...vel currently in the fuel tank If necessary add fresh unleaded gasoline with an octane rating of 87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of...

Страница 14: ...sized cord can overheat short out and cause a fire Usage Do not use fuel stabilizers with this generator doing so could cause damage to the generator or decrease the fuel and operating efficiency of t...

Страница 15: ...total wattage of the selected devices exceeds the rated wattage of the generator DO NOT connect all of the devices Select a combination of the electrical devices that will have a total wattage less t...

Страница 16: ...lt outlet Connect 12 Volt DC loads to the 12 Volt outlet Even though this generator has an overall rated wattage of 4000 do not attempt to draw more than 3500 Watts from the 120 Volt outlet Draws high...

Страница 17: ...enerator Failing to use the correct procedure can cause a battery to explode seriously injuring anyone nearby Keep heat sparks flame and smoking materials away from the battery To connect 12 Volt batt...

Страница 18: ...ocedures according to the schedule in Figure 7 Never perform maintenance procedures while this generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat...

Страница 19: ...ery 100 hours of use time The oil capacity for this Model GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator engine is 20 fluid oz 0 6 L To drain the oil from this generator It is necessar...

Страница 20: ...and install a new spark plug A F6TC spark plug such as NGK BPR5ES is recommended 4 Measure the spark plug electrode gap with a gauge The gap should be 0 028 0 031in 0 7 0 8mm See Figure 9 5 If re usin...

Страница 21: ...trouble persists call our customer help line at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time Symptom Cause Solution Engine switch is set to off Set engine switch to on Fuel valve is turned to c...

Страница 22: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 22 GEN4065 4000 SURGE WATTS 3250 RUNNING WATTS PORTABLE GENERATOR PARTS DIAGRAM Meijer com...

Страница 23: ...som 2 17 Bolt GB T5789 M6 12 8 18 Tank Cock 1 19 Fuel Pipe 1 20 Muffler Guard Cover 1 21 Bolt GB T5789 M6 16 2 22 Muffler 1 23 Bolt GB T16674 M8 20 3 24 Muffler Bracket 1 25 Nut GB T6184 M8 12 26 Engi...

Страница 24: ...GEN4065 4000 Surge Watts 3250 Running Watts Portable Generator 24 GEN4065 2011 08 Meijer com...

Отзывы: