NO.
PROBLEM
CAUSE
CORRECTIVE ACTION
1.
The Pilot burner does not
light
Gas runs out
Check and replace
The gas line to pilot burner is
closed
Check and repair
The hole of nozzle tip of Pilot
Burner is closed
Check and repair
2.
The burner flame yellow
The Primary Air Adjuster
closed
Check and open the Primary
Air Adjuster
The Burner is dirty
Clean with brush
3.
The burner does not light The gas cook damaged
Check and replace
4.
The pilot flame light but it
extinguishes again
Thermocouple slacked
Check and tight
The Thermocouple does not
produce voltage (MV)
Check with miliVoltmeter, if
the thermocouple is
Thermocouple is dirty
Check and clean
Trouble Shooting
T
roub
le
S
hoot
in
g
NAYATI
37
20151125
Содержание NGR 12-75 MR
Страница 13: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 Overall Dimension NGR 8 75 MR Fig 4 NAYATI 13 20151125...
Страница 14: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGR 12 75 MR Fig 5 NAYATI 14 20151125...
Страница 15: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 4 75 MR Fig 6 NAYATI 15 20151125...
Страница 16: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 8 75 MR Fig 7 NAYATI 16 20151125...
Страница 17: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 NGTR 12 75 MR Fig 8 NAYATI 17 20151125...
Страница 38: ...Gas Meritus GB Gas Range Series FRM PDE 03 04 CE Certificate CE Certificate NAYATI 38 20151125...