Naxer
Tech
Limited
4 |
P a g e
GPRS Initialisation
Format
%[CID]
INO
,
GPRS Dial No
,APN,
UserID
,
Pasword
,
UnitID
,
Control Center IP
,
Control Center
Port
,
Max Speed
,
CCIP2
,
CCPort2
CID
CID refers to Command Identification, a randomly created 8-digit command tag. (Max 8
digits)
INO
Command
GRPS Dial No.
SIM GPRS dialing number. (Max 15 characters) Usually not required
APN
GSM Operator GPRSAPN. (Max 31 characters)
User ID
SIM User ID for GPRS Access. (Max 15 characters)
Password
GSM Operator Password for GPRS Access (Max 15 characters)
Unit ID
Identification tag for GPRS device, issued by Control Base.
Control Center Domain/IP
Domain Name/IP address for GPRS data exchange at Control Base. (Max 15 characters)
Control Center Port
Port number for GPRS data exchange with Control Base. (Max 15 characters)
Max Speed
Over speed limit. (Min 0km/h Max 250km/h)
CC Domain/IP 2
Backup Domain Name/IP address for GPRS data exchange.
CC Port
Backup port number for GPRS data exchange.
Example
%25900213I
NO
,
*99#
,
Internet
,Telenor,Telenor,
00000001
,
gprs.naxertech.com
,
6081
,
180
,
203.
81.81.92
,
6081
Command Identification
25900213
GPRS Dial No
*99#
APN
Internet
User ID
Telenor
Password
Telenor
Unit ID
00000001
Control Center Domain
pegasus.naxertech.com
Control Center Port
6081
Max Speed
180 k m/h
CCIP 2
203.81.81.92
CC Port
6081
If max speed violation occurs, the device will send GPS data and status of the Control Base
through GPRS or SMS (backup). The Control Base shall return a PDU packet containing address
details and alert test in order to let the device send the text message to authorized contact
number. If no GPRS connection can be established, the SMS terminal at the Control Base shall
send SMS messages to authorized contact numbers itself.
%GPRS,0
Configure device to send data SMS if GPRS connection cannot be established at all occasions.
%GPRS,1
Configure device to send data only through GPRS. SMS fallback will only be used in case of
alarms.
Note:
When entering INI/ INO commands leave unassigned parameters empty but always include the comma.
(,)
In all the commands there is no space after the comma.
Control Center Number and Unit ID issued by the Control Base software cannot be changed after the initial %INI/ %INO
commands have been implemented.
Any further initializations with changes in Control Center Number have to be sent using the original GSM n umber, before you can
switch to a new Control Center Number.