Use the SETUP menu to customize the NAVMAN
fishfinder to suit the boat and individual
preferences.
On a FISH 4100 use the SETUP menu to:
·
Specify the trigger settings for the alarms (4-1).
·
Choose the depth units (4-2).
·
Turn the key beep on or off (4-3).
·
Choose the fish
symbol (4-4).
·
Adjust the
display contrast
(4-5).
·
Select language
and setup keel
offset (4-7).
Select MAIN MENU -
SETUP to display the
FISH 4100 SETUP
Menu. Press or
to select an option:
4 SETUP menu
On a FISH 4150 use the SETUP menu to:
·
Specify the trigger settings for the alarms (4-1).
·
Choose the units for depth, temperature and speed
(4-2).
·
Turn the key beep on or off (4-3).
·
Choose the fish symbol (4-4).
·
Calibrate the log, temperature and speed (4-6, 4-8).
·
Select the Trip Log or
the Total Log (4-6).
·
Zero the Trip Log or
zero all logs (4-6).
·
Adjust the display
contrast(4-5).
·
Select language, setup
keel offset and calibrate
speed and temperature
sensors (4-7, 4-8).
Select MAIN MENU - SETUP
to display the FISH 4150
SETUP Menu. Press or
to select an option:
Select MAIN MENU - SETUP - ALARMS to display the
available alarms. Press
or to select an option.
Alarms can be enabled to
automatically detect certain
conditions, such as the
water being too shallow.
Trigger settings can be
defined to suit the boat and
individual preferences. The
FISH 4100 ALARMS menu
is shown:
The FISH 4150 has two
extra alarms, TEMP
VALUE and TEMP RATE.
The beeper cycle is different for some alarms. All of
the alarm symbols and beeper cycles on the FISH
4100 are shown:
4-1 ALARMS menu
When an alarm condition is met, then:
·
The beeper sounds.
·
The ALARMS menu is displayed on the screen
with the activated alarm symbol(s) flashing.
Press any key to acknowledge the alarm, stop the
beeping and remove the ALARMS menu. This does
not disable the alarm. The symbol will continue to
flash until the alarm condition is no longer present.
Note: The FISH ALARM gives only three short beeps.
Alarms automatically re-enable
The TOO SHALLOW, TOO DEEP and LOW
BATTERY alarms automatically re-enable when the
value moves outside the alarm trigger setting.
The TEMP VALUE alarm automatically re-enables
when the temperature is more than 0.45°F (0.25°C)
above or below the alarm trigger setting.
The TEMP RATE alarm automatically re-enables
when the rate of temperature change falls below the
trigger setting by more than 0.2°F (0.1°C) per minute.
Symbol Alarm
Beeper Alarm condition is
Name
Cycle
met when:
Too
1
/
5
sec
the depth is less than
Shallow
the alarm trigger value
Too
1
/
2
sec
the depth is greater
Deep
than the alarm trigger
value
Fish
3 short an echo matches the
Alarm
beeps
profile of a fish
Low
1
/
2
sec
the battery voltage is
Battery
less than the alarm
trigger value
The alarm symbols and beeper cycles for the two
extra alarms on the FISH 4150 are shown:
Symbol Alarm
Beeper Alarm condition is
Name
Cycle
met when:
Temp
1
/
2
sec
the temperature equals
Value
the alarm trigger value
Temp
1
/
2
sec
the rate of change of
Rate
temperature equals the
alarm trigger value