9

NAVMAN D100 User Manual

Keel Offset

The NAVMAN D100 will normally display the
depth of water below the face of the transducer.
You may introduce a keel offset to reduce the
displayed depth or a waterline offset to increase
the displayed depth.

While in the 

Display Dampening mode, press

the 

 and 

 keys.

Use the 

 and 

 keys to set the required

value.

When correct value is displayed, press the 
key to exit.

Simulation Mode

The NAVMAN D100 has a simulation mode.

To enter this mode hold down the 

 key and

then switch on the power. The instrument will
remain in this mode even when power is
switched off.

Repeat this procedure to exit simulation mode.

Note:

Settings that are made while in

simulation mode will remain in effect

after returning to normal mode.

Secondary Functions

Set Display Dampening

Rough water conditions, schools of fish and
thermal layers cause erratic depth readings.
Display dampening controls the rate that the
displayed depth can change and will help remove
these variations. There are three levels of
dampening with d1 having the least effect and
d3 having the greatest effect. When operating in
shallow water or at high speed it is best to use a
low level of dampening.

Press and hold  the 

 and 

 keys for 3

seconds.

3 SECS

Use the 

 and 

 keys to set the required

value.

When correct value is displayed, press the 
key to exit.

Содержание D100

Страница 1: ...DEPTH NAVMAN NAVMAN...

Страница 2: ...g 5 Wiring Connection 6 Multiple Instruments 6 Operation 7 Select Units 7 Backlighting On Off 7 Depth Alarm On Off 7 Setting Alarms 8 Set Shallow Alarm 8 Set Deep Alarm 8 Secondary Functions 9 Set Dis...

Страница 3: ...res 0 5 to 67 fathoms or 3 to 400ft Alarms Shallow and deep water Audio and LCD flag Display unit selection Feet metres or fathoms keypad selectable Display Damping Three levels keypad selectable Keel...

Страница 4: ...The mounting surface must be flat Use the template to set the centre of the fixing hole Drill a 32mm 1 25 diameter mounting hole through the bulkhead Remove the fixing nut Peel the protective paper o...

Страница 5: ...provide protection for up to five 100 series instruments Multiple Instruments The NAVMAN D100 may be used as an individual instrument or connected with a number of other 100 series instruments to the...

Страница 6: ...hting On Off Simultaneously press the FEET MTRS FATH and keys to turn the backlight on Repeat this procedure to turn the lighting off FEET MTRS FATH SHALLOW DEEP FEET MTRS FATH SHALLOW DEEP Depth Alar...

Страница 7: ...er alarm sounds when the depth exceeds the selected value When the alarm is activated the beeper will sound continuously and the bell alarm symbol will flash Set Shallow Alarm MTRS SHALLOW Use the and...

Страница 8: ...n when power is switched off Repeat this procedure to exit simulation mode Note Settings that are made while in simulation mode will remain in effect after returning to normal mode Secondary Functions...

Страница 9: ...ngs while moored Check transducer for growth or multiple coats of paint Erratic readings while underway Cavitation air under the face of the transducer Review installation and reinstall if necessary W...

Страница 10: ...water performance and reduced deep water performance There are three values of transducer settings 1 to 3 The lower numbers improve the shallow water performance and may produce reliable readings to b...