Operation

Select Units

Use the 

 or 

 key to cycle through the

units of measure of feet, metres and fathoms.

FEET

MTRS

FATH

Backlighting On / Off

Simultaneously press the 

FEET

MTRS

FATH

 and 

 keys to

turn the backlight on. Repeat this procedure to
turn the lighting off.

FEET MTRS FATH SHALLOW DEEP

FEET MTRS FATH SHALLOW DEEP

Depth Alarm On / Off

Press the 

 key to turn the alarm on or off. The

bell symbol indicates the alarm is on. The bell will
flash when the alarm is activated.

MTRS

MTRS

Содержание D100

Страница 1: ...DEPTH NAVMAN NAVMAN...

Страница 2: ...g 5 Wiring Connection 6 Multiple Instruments 6 Operation 7 Select Units 7 Backlighting On Off 7 Depth Alarm On Off 7 Setting Alarms 8 Set Shallow Alarm 8 Set Deep Alarm 8 Secondary Functions 9 Set Dis...

Страница 3: ...res 0 5 to 67 fathoms or 3 to 400ft Alarms Shallow and deep water Audio and LCD flag Display unit selection Feet metres or fathoms keypad selectable Display Damping Three levels keypad selectable Keel...

Страница 4: ...The mounting surface must be flat Use the template to set the centre of the fixing hole Drill a 32mm 1 25 diameter mounting hole through the bulkhead Remove the fixing nut Peel the protective paper o...

Страница 5: ...provide protection for up to five 100 series instruments Multiple Instruments The NAVMAN D100 may be used as an individual instrument or connected with a number of other 100 series instruments to the...

Страница 6: ...hting On Off Simultaneously press the FEET MTRS FATH and keys to turn the backlight on Repeat this procedure to turn the lighting off FEET MTRS FATH SHALLOW DEEP FEET MTRS FATH SHALLOW DEEP Depth Alar...

Страница 7: ...er alarm sounds when the depth exceeds the selected value When the alarm is activated the beeper will sound continuously and the bell alarm symbol will flash Set Shallow Alarm MTRS SHALLOW Use the and...

Страница 8: ...n when power is switched off Repeat this procedure to exit simulation mode Note Settings that are made while in simulation mode will remain in effect after returning to normal mode Secondary Functions...

Страница 9: ...ngs while moored Check transducer for growth or multiple coats of paint Erratic readings while underway Cavitation air under the face of the transducer Review installation and reinstall if necessary W...

Страница 10: ...water performance and reduced deep water performance There are three values of transducer settings 1 to 3 The lower numbers improve the shallow water performance and may produce reliable readings to b...

Отзывы: