DEPTH
NAVMAN
Страница 1: ...DEPTH NAVMAN NAVMAN...
Страница 2: ...g 5 Wiring Connection 6 Multiple Instruments 6 Operation 7 Select Units 7 Backlighting On Off 7 Depth Alarm On Off 7 Setting Alarms 8 Set Shallow Alarm 8 Set Deep Alarm 8 Secondary Functions 9 Set Dis...
Страница 3: ...res 0 5 to 67 fathoms or 3 to 400ft Alarms Shallow and deep water Audio and LCD flag Display unit selection Feet metres or fathoms keypad selectable Display Damping Three levels keypad selectable Keel...
Страница 4: ...The mounting surface must be flat Use the template to set the centre of the fixing hole Drill a 32mm 1 25 diameter mounting hole through the bulkhead Remove the fixing nut Peel the protective paper o...
Страница 5: ...provide protection for up to five 100 series instruments Multiple Instruments The NAVMAN D100 may be used as an individual instrument or connected with a number of other 100 series instruments to the...
Страница 6: ...hting On Off Simultaneously press the FEET MTRS FATH and keys to turn the backlight on Repeat this procedure to turn the lighting off FEET MTRS FATH SHALLOW DEEP FEET MTRS FATH SHALLOW DEEP Depth Alar...
Страница 7: ...er alarm sounds when the depth exceeds the selected value When the alarm is activated the beeper will sound continuously and the bell alarm symbol will flash Set Shallow Alarm MTRS SHALLOW Use the and...
Страница 8: ...n when power is switched off Repeat this procedure to exit simulation mode Note Settings that are made while in simulation mode will remain in effect after returning to normal mode Secondary Functions...
Страница 9: ...ngs while moored Check transducer for growth or multiple coats of paint Erratic readings while underway Cavitation air under the face of the transducer Review installation and reinstall if necessary W...
Страница 10: ...water performance and reduced deep water performance There are three values of transducer settings 1 to 3 The lower numbers improve the shallow water performance and may produce reliable readings to b...