NAVITUS MCL 5.10 Скачать руководство пользователя страница 18

 

18 

11. 

Annex A. Controller menu and configuration settings 

 

Important: 

Menu item availability depends on the user rights and device modification. User 

rights can be managed only from the 

admin

 account secured by the admin password. 

 

 

Menu Item  

Description 

SMS command (smscfg:) 

0. EXIT 

Exit terminal mode 

 

1. Device 
configuration 

0. RETURN 

Back to the main menu 

 

1. 

Password/Keys

 

 

 

0. RETURN 

 

 

1. User password 

Set user password 

 

2. Admin password 

Set admin password 

 

3. User encryption key 

User encryption key 

 

4. Admin encryption key 

Admin encryption key 

 

2. Messaging

 

 

 

0. RETURN 

 

 

1. AC Fault report address 

Network address of web service 
processing alarm messages generated by 
meters 

 

2. AC Fault fix timeout 

Timeout 

 

3. AC Fault message send 
retry 

Times to retry sending the message 

 

4. AC Fault message send 
timeout 

Timeout period of acknowledgment 
reception of alarm message 

 

5. Plug&Play server address 

Plug & Play function alarm url address 

 

6. Plug&Play message send 
retry 

Times to retry sending the plug&play 
message 

 

7. Plug&Play message send 
timeout 

Message timeout 

 

3. Menu language of [Public] 

Menu language 

 

4. Menu language of [User] 

Menu language 

 

5. Menu language of [Admin] 

Menu language 

 

6. Menu language of 
[SuperAdmin] 

Menu language 

 

7. Device reboot period 

0. 

 

Reboot time value in minutes. If there are 
no queries coming via GPRS or CSD 
during specified time, controller will 
automatically reboot. After each GPRS or 
CSD query by reboot time is set to initial 
value 

 

8. Time zone 

Device time zone 

 

9. Firmware update mode 

Auto / Manual firmware download and 
update 

 

10. Modbus slave ID 

Modbus Slave ID 

 

11. Run firmware update 

Manually run firmware update 

 

12. Notes 

Notes about the device can be added here 

 

13. Restore factory defaults 

Restore system settings to factory defaults 
without loosing user data (provider 
settings, baud rate data is not affected) 

 

14. Reboot 

Restarts the controller immediately after 
pressing <Enter> key 

 

Содержание MCL 5.10

Страница 1: ...Controller with internal Quad band GSM GPRS 3G modem MCL 5 10 User manual Version 1 5 UAB NAVITUS LT Lithuania 2018...

Страница 2: ...functionality 4 0 1 5 2017 11 13 Byte timeout explained 4 0 Disclaimer The manufacturer guarantees that the following documentation is correct and intended for the device described The manufacturer ha...

Страница 3: ...CL 5 10 8 5 TECHNICAL CHARACTERISTICS 8 6 CONNECTING INTERFACES 9 6 1 CONNECTING A METER 10 7 LABELING 10 8 PARAMETERIZATION GUIDE 11 9 INITIAL INFORMATION 11 9 1 PROCEDURE OF LOCAL PARAMETERIZATION 1...

Страница 4: ...net Service Provider IP Internet Protocol address IMEI International Mobile Equipment Identity LED Light Emitting Diode N A Not Available Not Applicable PC Personal Computer PIN Personal Identificatio...

Страница 5: ...the GSM GPRS controller MCL 5 10 National wiring rules should be followed while installing and using the controller All equipment interconnected with this product should comply with the requirements o...

Страница 6: ...on socket X2 of the controller MCL 5 10 or by external power source Note The controller might be powered on by USB cable however due to the lack of current the gsm modem will not function Firmware and...

Страница 7: ...an be used for upload than average Reports Reports regarding signal strength IMEI IP address events can be sent as an UDP message to multiple IP addresses or phone number via SMS depending on APN and...

Страница 8: ...tics Power supply input voltage range 50 60Hz 90 V 264 V AC Power consumption a maximum in transmission mode b average in duty mode 10 VA 5 VA Internal backup power supply 450mAh LiPo battery mounted...

Страница 9: ...e The controller is powered on if any of the indicator defining signal strength is on pulse 6 Connecting interfaces Important Before proceeding please ensure the device will remain clean and dry durin...

Страница 10: ...ace see Figure 4 2 1 If there is more than one meter to be connected the parallel method must be used as indicated below 7 Labeling Principal controller information is marked on a label Label explanat...

Страница 11: ...Figure 6 2 1 Figure 6 2 2 or other software allowing connecting MCL 5 10 via device s RS232 interface After parameterization user must restart the controller s using the reset function in the menu You...

Страница 12: ...Figure 6 2 1 Figure 6 2 1 Select a port MCL is connected to Figure 6 2 2 Figure 6 2 2 After pressing OK in the COM Properties window figure 6 2 3 the settings are set to Auto detect by default figure...

Страница 13: ...13 Figure 6 2 4 To change the values 1 Press Disconnect button as shown on figure 6 2 5 arrow 1 2 Press Properties button as shown on figure 6 2 5 arrow 2 Figure 6 2 5...

Страница 14: ...figure button as shown on figure 6 2 6 arrow 3 4 Press OK button as shown on figure 6 2 6 arrow 4 Figure 6 2 6 5 Important Ensure that other settings of the connection are set as shown on figures 6 2...

Страница 15: ...15 6 The settings should change to 19200 8 N 1 as shown on figure 6 2 8 Figure 6 2 8 Important To load or re load controller s menu press button ESC on keyboard 3 times...

Страница 16: ...ice switches to the CSD mode There is an option to allow all calling from any number When the call is finished or the session is disconnected the device returns to GPRS mode More connection settings i...

Страница 17: ...nu interface to false Event Log Event Log Record Format Each event log record will register the following information Date and time of the event if known Type of the event Subject identity and or sour...

Страница 18: ...essage 5 Plug Play server address Plug Play function alarm url address 6 Plug Play message send retry Times to retry sending the plug play message 7 Plug Play message send timeout Message timeout 3 Me...

Страница 19: ...e main menu 1 Request to proceed timeout During the specified time the received request has to be send to a meter through RS485 RS232 out if it times out the request will be discarded 2 Data rate RS23...

Страница 20: ...k ID 5 2 Provider Name GSM Provider Network name 6 2 Provider FTP configuration 7 0 Return 8 1 FTP server URL FTP server address 9 2 FTP username FTP login username for firmware download 10 3 FTP pass...

Страница 21: ...s 7 6 Modem GPRS status Modem GPRS status 8 7 Network mode Network mode 9 8 SIM Status Status of the SIM card 9 Battery voltage Battery voltage 10 Battery charging Battery charging 11 Start battery te...

Страница 22: ...uence on the electricity meter s data MCL 5 10 system will restart automatically and will start operating as normal as soon as the voltage is restored The manufacturer has no obligation to service und...

Отзывы: