11
8. Parameterization Guide
9. Initial Information
MCL 5.10 controller using GPRS technology transmits the data of measurement equipment (meters). There is
an internal modem with a SIM card socket.
Connect the controller to the computer‘s COM or USB (depending on connection) port to start the setup.
Connect the antenna before switching the controller on. It is not necessary to insert a SIM card for
parameterization. If there is an ongoing data readout, it must be interrupted before parameterization.
9.1 Procedure of Local Parameterization
Access to the controller can be protected by a password. Several levels of users are possible: different admin
logins and user login. Each login has separate menus and control functions. Parameterization can be handled
using HyperTerminal (Figure 6.2-1, Figure 6.2-2) or other software allowing connecting MCL 5.10 via
device’s
RS232 interface.
After parameterization user must restart the controller's using the reset function in the menu.
You need to have the proper cable to connect from the X1 port on the device to
the RS232 port or the USB port of the computer
Important:
Parameterization may vary depending on connection interface type, device
version, administrator’s PC operating system region and version. Therefore figures and
menus given below may differ from actual due to software updates and upgrades.
Important:
It is required to disable PIN request on a SIM card, before inserting it in the
controller’s SIM socket
The settings of a COM port for parameterization are independent from the settings for
the data readout and the default settings are set as follows:
19200 bps, parity - none, 8
data bits and flow control - none
.
Important!
To load or re-
load controller’s menu press button
ESC
(on keyboard)
3 times
.