Switching On/Off and Troubleshooting
Chapter 3
Switching On/Off and Troubleshooting
Follow the procedures described below to switch
NAVIS NavDP 4000
on.
– Power the system ON — see Section 3.1, page 50. I/O Units and control computers will be started up.
– When the
DPShell
screen is displayed go to Section G, page 302.
If you don’t go to the next procedure the
Starter
screen will appear after a little while.
– When the
Starter
screen appears, select an appropriate item in the menu (Real Mode). For more detailed informa-
tion about the
Starter menu
The taking control procedures are described in Section 3.4, page 55. Keep in mind that the system should be switched
on.
For switching the system off (emergency or ordinary) refer to Section 3.6, page 55.
WARNING!
It is strongly prohibited to deenergize the system without observ-
ing the rules! In case the system deenergizing is necessary please
follow the switch-off instruction (Section 3.6, page 55).
3.1
Power On
3.1.1
Power On — DP-0 Class System
To switch a control system ON, press the
POWER
pushbutton installed in the corresponding Control Unit. Before
pressing this pushbutton, make sure about the position of the Mode Selector.
To switch the DP system ON, first set the Mode Selector to the
(OFF)Manual
position. See Figure 2.4.
3.1.2
Power On — DP1 Class System
Each of the IJ and DP control systems can be switched ON and OFF independently of each other. To switch a control
system ON, press the
POWER
pushbutton installed in the corresponding Control Unit. Before pressing this pushbutton,
make sure about the position of the Mode Selector.
If you are going to switch the IJ system ON, first set the Mode Selector in the
OFF (Manual)
or
DP
position.
To switch the DP system ON, first set the Mode Selector to the
OFF(Manual)
or
IJ
position.
See Figure 2.4.
3.1.3
Power On — DP2 Class System
Each of the IJ, DP-A and DP-B control systems can be switched ON and OFF independently of each other.
To switch a control system ON, press the
POWER
pushbutton installed in the corresponding Control Unit. Before
pressing this pushbutton, make sure about the position of the Mode Selector.
To switch any of the DP-A and DP-B systems ON, first set the Mode Selector to the (OFF)Manual or IJ position.
To switch the IJ system ON, first set the Mode Selector in the
OFF (Manual)
or
DP
position.
See Figure 2.4.
Doc. 000.JDP-10000-OME, rev.3.3.13/“2102.$–17A-Advanced”
50