List of settings 

General   

General settings 

Tanks 

Tank settings 

Wi-Fi 

Wi-Fi settings 

Info 

Device information 

Exit 

Exit and save settings 

 
Settings: General 

 

Default 

Range 

Description 

Language 

English 

English/Slovene 

Display language 

Back 

 

 

Return to main settings menu 

 

Settings: Tanks 

 

Default 

Range 

Description 

Tank 

– 4 

Selection of tank 

Sensor address 

– 255 

Sensor address, if receiver unit is part of set with included sensor, 
address comes preset. Otherwise address must be set manually. 

Signal 

 

 0 

– 115 dB 

Signal strength indication with icon and numerical display in dB unit 

Scan for sensors 

 

 

Automatic sensor search within range of the device 

Unit 

Lit 

Lit, hl, m3, gal 

Volume unit of tank 

Capacity 

1000 

– 9999 

Capacity of tank in selected unit 

Sensor type 

capacitive 

capacitive, 
ultrasonic, 
hydrostatic 

Sensor type selection, this will change the “Sensor Setup” menu to 
best fit selected type. Once selection is confirmed, “Sensor setup” 
menu will automatically open 

Sensor setup 

 

 

 

 

Capacitive 

 

 

 

 

 

Current level 

 

– 10000 

Current measured value. 

Please note that value does not represent 

level value, but rather coded measurement sent by sensor!

 

 

 

Save as empty

 

No

 

No/Yes

 

Save current measured level as minimal value 

– empty tank

 

 

 

Save as full

 

No

 

No/Yes

 

Save current measured level as maximal value 

– full tank

 

 

 

Level empty

 

1000

 

– 10000

 

Set value for empty tank 

– manual setting is possible

 

 

 

Level full

 

4000

 

– 10000

 

Set value for empty tank 

– manual setting is possible

 

 

 

Back

 

 

 

Return to Settings: Tanks 

 

 

Ultrasonic

 

 

 

 

 

 

Subtype 

SU10 

SU10, SU11, SU12 

Sensor model

 

 

 

Dist. empty 

150 cm 

– 500 

set distance from sensor to level Empty 

 

 

Dist. full 

8 cm 

– 500 

set distance from sensor to level Full 

 

 

Current level 

 

 

actual distance in mm 

 

 

Back 

 

 

Return to main settings menu 

 

Hydrostatic 

 

 

 

 

 

Subtype 

SP10_10 

SP10_10, SP10_15, 
SP10_20, SP10_25, 
SP10_30, SP10_35 
SP10_40, SP10_50, 
SP10_100, 
SP10_150, 
SP10_200 

Sensor model 

 

 

Level empty 

0 cm

 

0 - 2000 

set distance from sensor to level Empty 

 

 

Level full 

100 cm

 

0 - 2000 

set distance from sensor to level Full 

 

 

Current level 

0

 

0 - 4000 

Current measured value. 

Please note that value does not represent 

level value, but rather coded measurement sent by sensor!

 

 

Back 

 

 

Return to main settings menu 

Tank shape

 

rectangular 

rectangular, round, 
custom 

Tank shape impacts capacity and percentage calculations. Please 
select shape that fits your tank best 

when viewed from the side

 

Custom 

 

 

 

 

 

Level   Volume

 

0%:  0% 
5%:  5% 
10%:  10% 
20%:  20% 
… 
… 
70%:  70% 
80%:  80% 
95%:  95% 
100%:  100%

 

 

 

 

Back 

 

 

 

 

Settings: Wi-Fi 

 

Default 

Range 

Description 

Search Wi-Fi 

 

 

Wi-Fi access point search, with keys UP/DOWN select desired Wi-Fi 
access point name (SSID). After SSID is selected, device will 
automatically prompt for password. 

SSID  

 

32 characters 

Manual entry of access point name (SSID). After SSID is entered, 
device will automatically prompt for password. 

Password 

 

32 characters 

Wi-Fi Access point password entry. Leave blank for no password. 
After password is entered device will attempt Wi-Fi connection. 

Wi-Fi test 

 

 

Test Wi-Fi and internet connection. Displays current connection 
status. 

Back 

 

 

Return to main settings menu 

S/N 

 

 

Serial Number for registering/adding device on Level LiveData web 
portal. 