![NAVIS LW410HUB Скачать руководство пользователя страница 4](http://html2.mh-extra.com/html/navis/lw410hub/lw410hub_user-manual_4809620004.webp)
List of settings
General
General settings
Tanks
Tank settings
Wi-Fi
Wi-Fi settings
Info
Device information
Exit
Exit and save settings
Settings: General
Default
Range
Description
Language
English
English/Slovene
Display language
Back
Return to main settings menu
Settings: Tanks
Default
Range
Description
Tank
1
1
– 4
Selection of tank
Sensor address
1
1
– 255
Sensor address, if receiver unit is part of set with included sensor,
address comes preset. Otherwise address must be set manually.
Signal
0
– 115 dB
Signal strength indication with icon and numerical display in dB unit
Scan for sensors
Automatic sensor search within range of the device
Unit
Lit
Lit, hl, m3, gal
Volume unit of tank
Capacity
1000
0
– 9999
Capacity of tank in selected unit
Sensor type
capacitive
capacitive,
ultrasonic,
hydrostatic
Sensor type selection, this will change the “Sensor Setup” menu to
best fit selected type. Once selection is confirmed, “Sensor setup”
menu will automatically open
Sensor setup
Capacitive
Current level
0
– 10000
Current measured value.
Please note that value does not represent
level value, but rather coded measurement sent by sensor!
Save as empty
No
No/Yes
Save current measured level as minimal value
– empty tank
Save as full
No
No/Yes
Save current measured level as maximal value
– full tank
Level empty
1000
0
– 10000
Set value for empty tank
– manual setting is possible
Level full
4000
0
– 10000
Set value for empty tank
– manual setting is possible
Back
Return to Settings: Tanks
Ultrasonic
Subtype
SU10
SU10, SU11, SU12
Sensor model
Dist. empty
150 cm
0
– 500
set distance from sensor to level Empty
Dist. full
8 cm
0
– 500
set distance from sensor to level Full
Current level
actual distance in mm
Back
Return to main settings menu
Hydrostatic
Subtype
SP10_10
SP10_10, SP10_15,
SP10_20, SP10_25,
SP10_30, SP10_35
SP10_40, SP10_50,
SP10_100,
SP10_150,
SP10_200
Sensor model
Level empty
0 cm
0 - 2000
set distance from sensor to level Empty
Level full
100 cm
0 - 2000
set distance from sensor to level Full
Current level
0
0 - 4000
Current measured value.
Please note that value does not represent
level value, but rather coded measurement sent by sensor!
Back
Return to main settings menu
Tank shape
rectangular
rectangular, round,
custom
Tank shape impacts capacity and percentage calculations. Please
select shape that fits your tank best
when viewed from the side
.
Custom
Level Volume
0%: 0%
5%: 5%
10%: 10%
20%: 20%
…
…
70%: 70%
80%: 80%
95%: 95%
100%: 100%
Back
Settings: Wi-Fi
Default
Range
Description
Search Wi-Fi
Wi-Fi access point search, with keys UP/DOWN select desired Wi-Fi
access point name (SSID). After SSID is selected, device will
automatically prompt for password.
SSID
32 characters
Manual entry of access point name (SSID). After SSID is entered,
device will automatically prompt for password.
Password
32 characters
Wi-Fi Access point password entry. Leave blank for no password.
After password is entered device will attempt Wi-Fi connection.
Wi-Fi test
Test Wi-Fi and internet connection. Displays current connection
status.
Back
Return to main settings menu
S/N
Serial Number for registering/adding device on Level LiveData web
portal.