background image

NAVIS LEVEL LIVEDATA WEB PORTAL 

Every minute level data can also be transmitted to Navis Level LiveData portal over Wi-Fi connection. Level LiveData portal enables 
view of current level, history graphs and logs. 
For registration of receiver unit and account creation on Level LiveData web portal see user manual on portal. 

 
DISPLAY 

In basic mode of operation, single sensor is displayed (Image 2), user can switch between connected sensors by shortly pressing key 
SET. 
Last screen shows all connected sensors at the same time (up to 4 tanks) where more basic information about all sensors is shown 
(Image 3).  
 

 

                           

 

                                                 
                                                      

Image 2: Single sensor                               Image 3: Multiple sensors

 

 
Description of main screen for single sensor: 

Status bar: 

 

WiFi 

– icon shortly blinks, when data is sent via Wi-Fi to Navis Level LiveData web portal 

 

Signal strength indication 

 

Signal received icon blinks, when data is received from sensor 

 

Low battery icon is displayed when 

sensor

 

battery

 is running low (indication that sensor battery needs replacement) 

Graphical display of tank capacity: 

 

Shape of tank can be selected in menu and is displayed on screen, darkened section of tank is measured level.  

Tank temperature in °C, only with sensors which have integrated temperature measuring. 
Current tank capacity: 

 

Absolute value of liquid volume in selected volume unit 

 

Percentage of tank fullness 

Description of main screen with multiple sensors: 
Up to four sensors are displayed at the same time with only graphical representation. Non connected sensors are shown empty and 
provide no information. 

Status bar: 

 

Signal strength indicators of each tank 

 

Signal received icon blinks for each connected sensor, when data is received 

Graphical display of tank capacity: 

 

All tanks are displayed in rectangular shape, regardless of user settings, darkened section of tank is measured level. 

 
DISPLAY UNIT MASTER RESET 

Unplug receiver unit, wait for 30 seconds. Press and hold upper key and plug-

in the receiver. "Master reset…" should appear on screen 

and all settings, except sensor address, will be reset to default.   

 
DEVICE SETTINGS 

To enter device settings, press and hold SET key for more than two seconds. To move between sub-menus and settings use keys UP 
and DOWN. To exit the settings, select "Exit" or press and hold SET key for more than 2 seconds. Receiver will automatically exit 
settings if no key is pressed after 2 minutes. 
Data can be entered in two ways: 

1. 

Numerical data: 
Currently set value blinks, value can be increased by pressing UP or decreased by pressing DOWN key. With short presses, value 
will be changed by 1, by holding key value will be changed by 10, 100, 1000. Set value is confirmed by shortly pressing SET key.

 

2. 

Data from list: 
Device will offer list of possible settings, to move between them press keys UP or DOWN, confirm selection by shortly pressing 
SET key

3. 

Text input: 
On-screen keyboard will be displayed, press UP key to move left, DOWN key to move right, confirm selected letter by pressing 
SET key. Select SHIFT on keyboard to enter uppercase letters. Data is saved when OK is selected on keyboard.

 

 

 

Отзывы: