background image

2. Installation 

The NL-604P is designed for mounting on a trunk lid, car roof or on a boat. For this purpose, you 
must  choose  a  mounting  location,  where  the  material  is  hard  enough  to  absorb  the  pressure 
applied to the receiver, without denting in. Otherwise the rubber gasket on the mounting surface 
would not seal completely any more, and water might penetrate. The mounting examples shown 
for various situations provide maximum reception, since it is not hindered by the vehicle (e.g. by 
a window pane).

 

 

Do not carry out the mounting yourself, but rather let it be done by a specialist shop. If you carry 
out the mounting yourself, you may void the warranty. Please ask your dealer to what extent the 
personal mounting might influence the warranty and if it is necessary to have this work done by a 
specialist in order to keep the warranty.

 

 
Navilock is not responsible for wrong mounting, because we recommend that this should be done 
by a specialist. This is the reason we don’t offer any mounting instructions here. An experienced 
car repair shop has the expertise necessary to carry out the mounting.

 

 
3. Starting operation, e.g. with an USB adapter cable (article number 61264) 

3.1.

 Plug the USB cable into a free USB port on your notebook etc., and connect it with the 

NL-604P.  The  NL-604P  will  be  recognized  by  your  Windows  operating  system,  which  will 
attempt to install a driver. Abort this process, and start the driver installation of the USB cable 
from  the  CD-ROM,  or  download  the  driver  from  the  Navilock  website.  Follow  the  installation 
instructions.  After  the  installation  is  completed,  re-start  your  computer.  Then  the  GPS  COM 
port  will  be  available  in  the  Device  Manager  under  Connections.  Set  this  port  in  your 
navigation or route planner software. Do not use another program which accesses this port at 
the same time.

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание NL-604P

Страница 1: ...NL 604P operation manual 61842 ...

Страница 2: ...ttery NOTE RECYCLE OR DISPOSE OF USED BATTERIES OR RECHARGEABLE BATTERIES IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS AND THE INSTRUCTIONS INCLUDED WITH THE PRODUCT PRECAUTIONS REGARDING DIRECT SUNLIGHT Make sure the unit is not exposed to very high humidity and temperatures Never leave the unit the battery or the rechargeable battery for an extended period in a vehicle or plate where the temper...

Страница 3: ...n order to keep the warranty Navilock is not responsible for wrong mounting because we recommend that this should be done by a specialist This is the reason we don t offer any mounting instructions here An experienced car repair shop has the expertise necessary to carry out the mounting 3 Starting operation e g with an USB adapter cable article number 61264 3 1 Plug the USB cable into a free USB p...

Страница 4: ... in the u Center but you cannot find a receiver in the application software the connection problem is not with the receiver but with the selected software setting In this case the software manufacturer support center may be able to help you After starting the u Center software check the functionality of your NL 604P 1 Selecting the COM port 2 Selecting the baud rate 3 Downloading Assist GPS and up...

Страница 5: ...guration mode There you can select different setting functions More detailed information can be found in the current documentation at the URL http www u blox com To switch the NL 604P to EGNOS reception please click in the menu bar on item 6 A small window will open in which all settings for the receiver can be made ...

Страница 6: ...ently of the reception conditions Without A GPS a GPS receiver must localize at least 4 satellites in the direct line of vision and then download their location data This process takes 30 seconds under optimal reception conditions but under less favorable conditions it may take much longer e g in an urban environment or in a building where the GPS reception is weaker AssistNow sends the data direc...

Страница 7: ...M automatically Please check under http msdn2 microsoft com en us library Aa969329 aspx The Navilock repair center tries to be as obliging as possible so please tell us the real reason for the defect During the error analysis we can generally detect if the cause for the defect was an external cause water damage dropping over voltage or the wrong handling of the unit Failures are often the result o...

Страница 8: ...art 3 5s average with ephemerides and almanac Warm start 25s average with ephemeredes but without almanac Cold start 30s average neither ephemerides nor almanac Re Acquisition 1s average recovery time after interruption UP DATE Rate 5Hz Dynamic prerequisites Acceleration limit smaller than 4g Height limit 18 000 meters 60000 feet maximal Speed limit 515 meter sec 1000 knots maximal Performance Pow...

Страница 9: ...u will be charged a connection fee for a telephone call to Germany Berlin in accordance with the connection fee overview of your telephone service provider Callers from Germany who subscribed to a national telephone flat rate service and can call nation wide fixed telephone numbers free of charge can call us without incurring additional charges You can also find current product information on our ...

Страница 10: ... with natural resources more economically In addition re using electronic waste contributes to the preservation of the environment and human health Additional information regarding the disposal of electric and electronic devices their re usage and the collection sites can be found at your local authorities disposal companies specialist shops and the manufacturer of the product RoHS conformity This...

Отзывы: