1. Introduction 
The NL-604P is a serial GPS receiver with an internal antenna and a ublox6 GPS & GALILEO 
SuperSense

®

  GPS/Galileo  chip  set.  The  serial  port  enables  the  connection  with  a  notebook, 

UMPC, tablet PC or car PC. Thanks to its universal MD6 connector, it can be used on almost all 
devices by means of an adapter cable. Adapter cables are available optionally.

 

 

1.1. Contents* 

1x Navilock NL-604P 
1x set mounting material 

(washer, circlip, nut)

 

1x 8cm CD ROM including operation manual 
 

 
* Before using the device, please make sure that all the parts are included in the package. If any 
parts are missing or damaged, please contact your dealer immediately.

 

 

Important health and safety information 

When  using  this  product,  take  the  following  precautions  in  order  to  avoid  possible  damages  and  legal  consequences.  Always 
follow all safety and operation manuals exactly and keep them for future reference. Observe all warnings in the operation manual 
and on the product. In order to avoid injuries, electrocution, fire and damages to the product, observe the following precautions:

 

 

ELECTRIC SECURITY 

This product is designed for operation with power supply via the USB port. Any other operation mode can be dangerous and may 
void the warranty claims for this product. This unit contains an internal back-up battery.

 

 

NOTE: 

RECYCLE OR DISPOSE OF USED BATTERIES OR RECHARGEABLE BATTERIES IN 

ACCORDANCE  WITH  ALL  APPLICABLE  REGULATIONS  AND  THE  INSTRUCTIONS 
INCLUDED WITH THE PRODUCT.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

PRECAUTIONS REGARDING DIRECT SUNLIGHT 

Make sure the unit is not exposed to very high humidity and temperatures. Never leave the unit, the battery or the rechargeable 
battery for an extended period in a vehicle or plate, where the temperature can increase to over 60°C (140°F), for example on the 
dashboard  of  a  car,  the  window  sill  or  behind  a  pane  of  glass,  which  is  directly  exposed  to  the  sun  or  very  strong  UV  light. 
Otherwise the unit or the vehicle may be damaged, and the battery or the rechargeable battery may overheat.

 

 

Damages requiring repairs 

Disconnect  the  unit  from  the  AC  supply  in  the  following  cases;  also  disconnect  the  rechargeable  battery  and  contact  an 
authorized repair man or your dealer. 

• 

Liquid or an object has entered the product. 

• 

The product has fallen down or was damaged. 

• 

There are visible signs of overheating. 

• When operated normally, the product does not function flawlessly. 

 

Avoid using the unit directly after strong temperature changes. 

If  the  unit  is  exposed  to  strong  temperature  and  humidity  fluctuations,  condensation  can  form  in  the  unit.  In  order  to  avoid 
damages to the unit, please wait until the condensation has dried off before using the unit.

 

 

 

NOTE: 

If  you  bring  the  unit  from  a  cold  to  a  warm  environment,  or  vice  versa,  first  let  it  get 

accustomed to the new temperature before turning it on.

 

Содержание NL-604P

Страница 1: ...NL 604P operation manual 61842 ...

Страница 2: ...ttery NOTE RECYCLE OR DISPOSE OF USED BATTERIES OR RECHARGEABLE BATTERIES IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS AND THE INSTRUCTIONS INCLUDED WITH THE PRODUCT PRECAUTIONS REGARDING DIRECT SUNLIGHT Make sure the unit is not exposed to very high humidity and temperatures Never leave the unit the battery or the rechargeable battery for an extended period in a vehicle or plate where the temper...

Страница 3: ...n order to keep the warranty Navilock is not responsible for wrong mounting because we recommend that this should be done by a specialist This is the reason we don t offer any mounting instructions here An experienced car repair shop has the expertise necessary to carry out the mounting 3 Starting operation e g with an USB adapter cable article number 61264 3 1 Plug the USB cable into a free USB p...

Страница 4: ... in the u Center but you cannot find a receiver in the application software the connection problem is not with the receiver but with the selected software setting In this case the software manufacturer support center may be able to help you After starting the u Center software check the functionality of your NL 604P 1 Selecting the COM port 2 Selecting the baud rate 3 Downloading Assist GPS and up...

Страница 5: ...guration mode There you can select different setting functions More detailed information can be found in the current documentation at the URL http www u blox com To switch the NL 604P to EGNOS reception please click in the menu bar on item 6 A small window will open in which all settings for the receiver can be made ...

Страница 6: ...ently of the reception conditions Without A GPS a GPS receiver must localize at least 4 satellites in the direct line of vision and then download their location data This process takes 30 seconds under optimal reception conditions but under less favorable conditions it may take much longer e g in an urban environment or in a building where the GPS reception is weaker AssistNow sends the data direc...

Страница 7: ...M automatically Please check under http msdn2 microsoft com en us library Aa969329 aspx The Navilock repair center tries to be as obliging as possible so please tell us the real reason for the defect During the error analysis we can generally detect if the cause for the defect was an external cause water damage dropping over voltage or the wrong handling of the unit Failures are often the result o...

Страница 8: ...art 3 5s average with ephemerides and almanac Warm start 25s average with ephemeredes but without almanac Cold start 30s average neither ephemerides nor almanac Re Acquisition 1s average recovery time after interruption UP DATE Rate 5Hz Dynamic prerequisites Acceleration limit smaller than 4g Height limit 18 000 meters 60000 feet maximal Speed limit 515 meter sec 1000 knots maximal Performance Pow...

Страница 9: ...u will be charged a connection fee for a telephone call to Germany Berlin in accordance with the connection fee overview of your telephone service provider Callers from Germany who subscribed to a national telephone flat rate service and can call nation wide fixed telephone numbers free of charge can call us without incurring additional charges You can also find current product information on our ...

Страница 10: ... with natural resources more economically In addition re using electronic waste contributes to the preservation of the environment and human health Additional information regarding the disposal of electric and electronic devices their re usage and the collection sites can be found at your local authorities disposal companies specialist shops and the manufacturer of the product RoHS conformity This...

Отзывы: