background image

1. Introduction 

 

The NL-6003P is a MD6/serial GNSS receiver with internal antenna and ublox NEO-6P GPS 
module. This module allows a positioning accuracy of under one metre through a combination of 
PPP (Precision point Positioning) and SBAS technologies. The MD6/serial interface enables 
connection to a notebook, UMPC, tablet or car PC. The receiver's bottom side is rubberized and 
magnetic, which allows for universal positioning. Thanks to its compact design and its high 
precision positioning technology, it is the ideal companion at work and at leisure. 

 

Contents* 
 

• 

1x Navilock NL-6003P  

• 

1x 8 cm CD ROM including operation manual 

 

* Before using the device, please make sure that all the parts are included in the package. If any 
parts are missing or damaged, please contact your dealer immediately.  

 

Important health and safety information 

 

When using this product, take the following precautions in order to avoid possible damages and legal consequences. Always follow 
all safety and operation manuals exactly and keep them for future reference. Observe all warnings in the operation manual and on the 
product. In order to avoid injuries, electrocution, fire and damages to the product, observe the following precautions:  

 

ELECTRIC SECURITY 

 

This product is designed for operation with power supply via the USB or PS/2 port. Any other operation mode can be dangerous and 
may void the warranty claims for this product. This unit contains an internal back-up battery.  

 

NOTE: 

RECYCLE OR DISPOSE OF USED BATTERIES OR RECHARGEABLE BATTERIES IN 

ACCORDANCE WITH ALL APPLICABLE REGULATIONS AND THE INSTRUCTIONS 
INCLUDED WITH THE PRODUCT.

 

 

 

 
 
 

PRECAUTIONS REGARDING DIRECT SUNLIGHT 

Make sure the unit is not exposed to very high humidity and temperatures. Never leave the unit, the battery or the rechargeable 
battery for an extended period in a vehicle or plate, where the temperature can increase to over 60°C (140°F), for example on the 
dashboard of a car, the window sill or behind a pane of glass, which is directly exposed to the sun or very strong UV light. Otherwise 
the unit or the vehicle may be damaged, and the battery or the rechargeable battery may overheat.

 

 

Damages requiring repairs 

Disconnect the unit from the AC supply in the following cases; also disconnect the rechargeable battery and contact an authorized 
repair man or your dealer. 

• 

Liquid or an object has entered the product. 

• 

The product has fallen down or was damaged. 

• 

There are visible signs of overheating. 

• When operated normally, the product does not function flawlessly. 
 

Avoid using the unit directly after strong temperature changes. 

If the unit is exposed to strong temperature and humidity fluctuations, condensation can form in the unit. In order to avoid damage to 
the unit, please wait until the condensation has dried off before using the unit.

 

 

 

NOTE: 

If you bring the unit from a cold to a warm environment, or vice versa, first let it get 

accustomed to the new temperature before turning it on.

 

 
 

Содержание NL-6003P

Страница 1: ...NL 6003P u blox NEO 6P MD6 seriell Receiver Operation manual 62457 ...

Страница 2: ... warranty claims for this product This unit contains an internal back up battery NOTE RECYCLE OR DISPOSE OF USED BATTERIES OR RECHARGEABLE BATTERIES IN ACCORDANCE WITH ALL APPLICABLE REGULATIONS AND THE INSTRUCTIONS INCLUDED WITH THE PRODUCT PRECAUTIONS REGARDING DIRECT SUNLIGHT Make sure the unit is not exposed to very high humidity and temperatures Never leave the unit the battery or the recharg...

Страница 3: ...se restart your computer after the installation is completed Afterwards the GPS COM Port will be available in the device manager under connections Set this port in your navigation or route planner software Do not simultaneously use any other program accessing this COM Port 3 LED indicator flashes with satfix lights without satfix 4 Application environment The NL 6003P can be used as a MD6 Serial G...

Страница 4: ...ting the baud rate 3 Downloading Assist GPS and updating the receiver 4 Visual display of the NMEA data 5 Configuration manager 6 NMEA UBX message console 7 NMEA text console As seen below you can set up your u Center by yourself Everything important can be connected and displayed immediately The green bars at the bottom of the picture show the reception quality at your position If no bars are dis...

Страница 5: ...le applications especially those that require a continuous state of readiness for example applications for fleet management or GNSS capable hand held devices whose users would like to access local services immediately independently of the reception conditions Without A GPS a GNSS receiver must localize at least 4 satellites in direct line of vision and then download their location data This proces...

Страница 6: ...trong rain when it was mounted on a car roof Do not connect the receiver with the notebook etc under any circumstances because it will otherwise be completely and irreparably destroyed Return the receiver to our support center mentioning water damage The support center will disassemble the receiver dry it and check its functionality The Navilock repair center tries to be as obliging as possible so...

Страница 7: ... s Date WGS 84 Protocol NMEA 0183 V3 01 GGA GSA GSV RMC VTG Detection rates Hot start 1 s average with ephemerides and almanac Warm start 32 s average with ephemeredes but without almanac Cold start 32 s average neither ephemerides nor almanac Re Acquisition 1 s average recovery time after interruption Update rate 1 Hz Dynamic prerequisites Acceleration limit smaller than 4 g Height limit 50000 m ...

Страница 8: ...pm You will be charged a connection fee for a telephone call to Germany Berlin in accordance with the connection fee overview of your telephone service provider Callers from Germany who subscribed to a national telephone flat rate service and can call nation wide fixed telephone numbers free of charge can call us without incurring additional charges You can also find current product information on...

Страница 9: ...cally In addition re using electronic waste contributes to the preservation of the environment and human health Additional information regarding the disposal of electric and electronic devices their re usage and the collection sites can be found at your local authorities disposal companies specialist shops and the manufacturer of the product RoHS conformity This product complies with the directive...