26
Checklist before Reporting Failure
Symptom
Checklist
Solution
Heating isn’t working.
Isn’t temperature setting too low?
Press either or button then turn the dial
clockwise to increase heating temperature.
Isn’t heating switched off or set as
only hot water?
Please check if programmed time
is off
Please adjust the time program for heating
Are you using hot water?
Heating does not supply when hot water is on
Isn’t heating valve for each room
locked?
Please open heating valve for each room
Isn’t heating filter blocked?
Please clean heating filter.
Is heating pipe filled with air?
Open the air removal valve on the top of
distributor for each room to remove air from
heating pipes.