12 Maintaining the Water Heater
Press the Power button on the front panel to turn off the water
1.
heater.
Disconnect the power supply to the water heater.
2.
Close the “C” and “D” valves on the hot and cold water lines.
3.
Connect one tube to the “A” valve and place the free end in the
4.
bucket.
Connect one of the tubes to the circulation pump outlet and
5.
the cold water line at the “B” valve.
Connect one tube to the circulation pump inlet and place the
6.
free end in the bucket.
Pour the cleaning solution into the bucket.
7.
Open both “A” and “B” valves.
8.
Turn on the circulation pump and allow the solution to
9.
circulate through the water heater for at least 45 minutes.
Rinse the cleaning solution from the water heater:
10.
a. Remove the free end of the drain tube from the bucket and
place it in the condensate drain or laundry tub (wherever the
water heater drains).
b. Close the “B” valve and open the “D” valve. Do not open the
“C” valve yet.
c. Allow water to flow through the water heater for 5 minutes.
d. Close the “A” valve and open the “C” valve.
Disconnect all tubes.
11.
Remove the cold water inlet filter from the water heater and
12.
clean out any residue.
Reinsert the filter and ensure the filter cap is securely
13.
tightened.
Reconnect the power supply to the Water Heater.
14.
Press the Power button on the front panel to turn on the water
15.
heater.
4.4 Cleaning the Inlet Water Filter and
Recirculation Inlet Filter
To clean the filters:
Drain the water heater. Refer to “
1.
4.2 Draining the Water
Heater” on page 10.
While the filters are removed, rinse it with clean running water
2.
(cold) and, if necessary, scrub it clean with a brush.
Cold Water
Inlet Filter
Recirculation
Inlet Filter
(“A” model only)
Reinsert and tighten the filters.
3.
Refill the water heater. Refer to “
4.
4.2 Draining the Water
Heater” on page 10.
Cold Water
Inlet Filter
Recirculation Inlet Filter
(“A” model only)
Содержание NPE-180A