32 Installing the Water Heater
●
2" or 3" Two-pipe Vertical Venting – Intake and exhaust pipes do
not have to terminate in the same area.
12" (300mm) min.
12" (300mm) min.
36" (900mm) min.
12" (300mm) min.
From any
obstruction (above,
below, left, or right)
Exhaust Gas
Intake Air
Concentric Roof Venting
●
Maintain 12" (300mm) min.
(18" (450mm) min. for Canada)
Clearance above highest
anticipated snow level. Maximum
of 24" (600mm) above roof
Vent
Vent
Combustion Air
Combustion Air
Outdoor Installation
Outdoor installation should only be considered in mild climates.
Freezing temperatures or contaminated air can damage the
water heater. When installing the water heater outdoors, maintain
clearances from building openings, as described in the “Non-Direct
Venting (Single Pipe)“ section on page 28. Outdoor installation
areas should be in an open, unroofed area and should allow for the
following minimum clearances from the water heater:
Side
Side
Front
Bottom
Back
Intake Air
Exhaust Gas
Top
Bottom
12"
Back
0.5"
Sides
3"
Front
24"
Top
36"
When installing a water heater outdoors, follow these guidelines:
The Navien Outdoor Vent Kit must be used to ensure proper
●
operation of the water heater.
Ensure that there is plenty of clearance around the air intake and
●
that it is adequately protected to prevent any debris, liquids, or
flammable gases from entering the air intake.
If the water heater is installed under an eave, maintain a
●
clearance of 3 feet or more from the eave to the top of the water
heater vent terminals.