STEP 3    After Installing 

  Opening All the Valves 

 

 

  Operating the Boiler 

 

 

  Measuring the Inlet Gas Pressure 

 

 

 

  Installing the Front Cover 

 

 

  Final Check 

 

A trial run should be performed in accordance with the Installation checklist listed in 
the boiler’s Installation & Operation Manual.

 

Shut off the manual gas 
valve. 

Closed 

Remove the front cover by 
loosening the 4 screws. 

Loosen the screw indicated in the 
figure and connect a manometer 
to the pressure port. Reset the 
manometer to zero before use. 

Open 

Check the inlet gas pressure reading on the manometer. 

Re-open the manual gas valve 
and check for leaks. 

Operate multiple zones that to 
ramp the boiler up to its 

maximum firing rate. 

Adjust the inlet gas pressure 

with gas regulator. 

Gas supply 

If it is out of 

the range, 

  NG:3.5

~10.5

WC 

  L P: 8 . 0

~ 1 3 . 5

W C 

Recommended Gas Pressure Settings: 

1.

 

Turn on the boiler. On the Front 

Panel press the Diagnostics 

button for over 5 seconds until 

1.PAR

  is displayed. 

2.

 

Press the + (Up) button two times 

to change the display to

3.OPR

3.

 

Press the + (Up) button until 

MAX2

  is displayed.   

4.

 

Press the Reset button twice 

to return to normal operation 

mode. 

5.

 

Run space heating. The gas in 

the gas supply line will be 

purged. 

6.

 

Leave the boiler on until the 

boiler shuts down due to a 

lack of gas supply, and then 

turn off the boiler. 

Power ON 

Adjust Temperatures 

 

View Basic Information 

Resetting the Boiler 

When the power is on, the boiler 
supply water temperature will 
appear with the water pressure 
on the front panel display at 

5 second intervals. 

1.

 

Press the Mode button three 

times. “INFO” will appear on 

the display.   

2.

 

Press the + (Up) or – (Down) 

buttons to switch between 

the information types. 

If an error message appears, you 
can try resetting the boiler to 
resolve the problem.   

Note 

Space Heating Temperature   

1.

 

Press the Mode button 

once. The space heating 

icon turns on.   

2.

 

Press the + (Up) or – (Down) 

buttons until the desired 

temperature appears on 

the display. 

If resetting does not solve 
the problem, refer to the 
troubleshooting section of 
the User’s Information 
Manual or contact the 
service center. 
 

DHW Indirect Supply Temperature 

 

 

 

 

 

 

 

 

 

 

3.

 

Press the Mode button 

twice. The DHW heating 

icon turns on.   

4.

 

Press the + (Up) or – (Down) 

buttons until the desired 

temperature appears on the 

display. 

Shut-off Valves 

Navien, Inc. 
20 Goodyear, Irvine, CA 92618 
Tel: (949) 420-0420,    Fax: (949) 420-0430 

www.navien.com 

Gas Valve 

Space Heating System Valves 

Drip rig 

Closed  Open 

Open 

Содержание NHB-55

Страница 1: ...boiler Gas supplies should be connected by a licensed professional only The appliance and its gas connection must be leak tested before placing the appliance in operation This boiler cannot be converted from natural gas to propane or vice versa without a Navien gas conversion kit Do not attempt a field conversion of this boiler without a Navien gas conversion kit Doing so will result in dangerous ...

Страница 2: ...verheating Make up Water Pressure Relief Valve A pressure relief valve must be installed when installing pipings for a heating system From System Air Vent Cap Space Heating Return Before filling the boiler remove the air vent cap to allow the system to fill properly Replace the cap when the system is full The Navien NHB boilers have a top connection for an air vent An air vent must be installed to...

Страница 3: ...low Navien recommended venting materials Locale Recommended Vent Materials USA PVC Schedule 40 Solid core CPVC Schedule 40 or 80 Solid core Approved Polypropylene Canada Type BH Special Gas Vent Class IIA PVC Type BH Special Gas Vent Class IIB CPVC Type BH Special Gas Class IIC Polypropylene For installation in Canada field supplied plastic vent piping must comply with CAN CGA B149 1 latest editio...

Страница 4: ...mal operation mode 5 Run space heating The gas in the gas supply line will be purged 6 Leave the boiler on until the boiler shuts down due to a lack of gas supply and then turn off the boiler Power ON Adjust Temperatures View Basic Information Resetting the Boiler When the power is on the boiler supply water temperature will appear with the water pressure on the front panel display at 5 second int...

Отзывы: