26

Warranty

Effective

This 5/10 year limited warranty on heat  exchangers, 
3/5 year limited warranty on parts, and 1 year 
limited-labor warranty (“Warranty”) covers defects 
in materials or workmanship when the Navien 
NFC-H Boiler (“Product”) is installed by a properly 
licensed plumber or contractor and operated in 
strict compliance with the Installation & Operations 
manual procedures, subject to the terms within this 
Warranty document.   Improper installation or use 
will void this Warranty. This Warranty runs from date 
of installation and extends to the original purchaser 
and subsequent owners, but only while the Product 
remains at the site of the original installation. This 
Warranty includes a limited warranty as set forth 
below.

What is covered?

Subject to the foregoing terms, Navien will 
repair or replace the covered Product or any part 
or component that is defective in materials or 
workmanship for a period of five (5) years in regard 
to parts and up to ten (10) Years  in regard to the 
heat-exchanger.  Navien will pay labor charges 
for the repair subject to Navien’s prior  written 
approval and in accordance with Navien’s schedule 
of approved labor allowances for a period of one 
(1) year from the date of installation. All repair parts 
must be genuine Navien parts.   All repairs and 
replacements must be performed by an individual 
or servicing company that is properly licensed to do 
the type of repair.

When the Product is or has ever been used for 
anything other than single family residential 
application (hereinafter “Commercial”) then the 
parts warranty will be reduced to three (3) years and 
the heat exchanger warranty to five (5) years.

During the applicable warranty period, replacement 
of the Product or components may be authorized 
by Navien only.  Navien does not authorize any 
person or company to assume for it any obligation 
or liability in connection with the replacement of 
the Product or its components.  If it is determined 
that repair or replacement of a part, under warranty, 
is not possible, the Product will be replaced with 
a new Product having at least the same BTU 
capacity as the product at issue.  The replacement 
component or product will be warranted only for 
the unexpired portion of the applicable warranty 
period for the original component or Product.

Applicable Warranty Periods

Period of Coverage

Residential*

Commercial

Labor

1 year

Labor

1 year

Parts

5 years

Parts

3 years

Heat 
Exchanger

10 years

Heat 
Exchanger

5 years

* Applies only to single family, residential locations.

How do I get service?

You must contact the original installer of your 
Product.  Your installer will need to contact Navien 
to report the issue. If the original installer cannot 
be identified or you no longer choose to use that 
service provider, you may choose any service 
provider who is properly licensed to complete 
the necessary repair. The  installer  and/or  service  
provider  must  comply  with  Navien’s  warranty 
service and return policy procedures as available 
on Navien’s website including contacting Navien’s 
Technical Support Department at (800) 519-8794, 
option 2, prior to commencing any service.

Proof of the date of installation must be provided to 
Navien.  At Navien’s request, the defective Product 
or part must be returned to Navien. When the 
Product is installed in new construction, the date 
of installation shall be established as the date upon 
which the end-user takes title to the real property. If 
proof of the installation date is unavailable, then six 
months after the date of manufacture will be used.

LIMITED WARRANTY NAVIEN, INC.

Содержание NFC-250/200H

Страница 1: ...ur gas supplier call the fire department Installationandservicemustbeperformedbyaqualifiedinstaller serviceagencyorthegas supplier Theinstallationmustconformwithlocalcodesor intheabsenceoflocalcodes t...

Страница 2: ...On or Off 10 3 2 Adjusting the System Temperatures 10 3 3 Accessing Basic Menu Items 12 3 4 Resetting the Boiler 13 4 Maintaining the Boiler 14 4 1 Cleaning the Boiler 14 4 2 Draining the Boiler 14 4...

Страница 3: ...pliance does not have a pilot It is equipped with an ignition device which automatically lights the burner Do not try to light the burner by hand B BEFORE OPERATING smell all around the appliance area...

Страница 4: ...boiler with the front cover opened Doing so may result in fire or carbon monoxide CO poisoning which may result inpropertydamage personalinjury ordeath Do not operate this boiler without proper ventin...

Страница 5: ...o property damage personal injury or death and will void your warranty Do not operate the boiler if you feel something is wrong with it Doing so may result in product damage or personal injury Do not...

Страница 6: ...ater temperatures at or above 125 F 52 C can cause instant scalding severe burns or death Before you decide to change the temperature setting read the following charts carefully Water Temperature Time...

Страница 7: ...n Each boiler is specially grounded both internally and externally to protect against lightning strikes Carbon Monoxide Protection The boiler is designed to maintain a safe air to gas ratio and combus...

Страница 8: ...eeze mode Auto air purge Displayed when an auto air purge is being performed e Cascade Main mode Flashes when configuring a cascade system Turns on solid if the boiler is set as the Main unit in a cas...

Страница 9: ...for the boiler s operation such as space heating and DHW supply temperatures Refer to the following table for detailed information a Back button Return to the previous menu or screen b Mode button En...

Страница 10: ...the boiler on or off press the Power button When the power is on the boiler automatically enters normal operation mode and the boiler s operating conditions are displayed on the screen Note The boile...

Страница 11: ...on to return to normal operation mode or rotate the Command dial to adjust other operation conditions You can adjust the temperature while the highlighted section is flashing Once the flashing stops t...

Страница 12: ...ter Pressure Water pressure psi 17 Flame Value Flame detector AD value Flame On 8bit AD values equal to or lower than 70 Flame Off 8bit AD values equal to or higher than 175 18 Fan Target RPM Set fan...

Страница 13: ...xhaust temperature F 25 Outdoor Reset Outdoor reset status Enable Disable 26 Outdoor Reset Curve Outdoor reset curve load type displayed when the outdoor reset option 25 Outdoor Reset is enabled 1 Fin...

Страница 14: ...t it is not waterproof Keep it as dry as possible 4 2 Draining the Boiler You will need to drain the boiler under certain circumstances such as when the boiler is not used for an extended period of ti...

Страница 15: ...ded or as part of the annual maintenance To clean the air intake filter 1 Press the Power button on the front panel to turn off the boiler 2 Disconnect the power supply to the boiler 3 Unfasten the 4...

Страница 16: ...Place the filter assembly back into the boiler and secure it with the screw 9 Replace the front cover 10 Reconnect the power supply to the boiler 11 Press the Power button on the front panel to turn o...

Страница 17: ...boiler at the beginning of every heating season and or when there is a problem 4 4 Protecting the Boiler from Freezing CAUTION Damage due to freezing is not covered by the Navien limited warranty Fre...

Страница 18: ...severe personal injury death or substantial property damage The boiler should be inspected annually only by a qualified service technician In addition the maintenance and care of the boiler must be pe...

Страница 19: ...s Addressing the Reported Problems Inspect any problems reported by the owner and correct before proceeding Inspecting the Installation Area 1 Verify that boiler area is free of any combustible materi...

Страница 20: ...er place of disposal Otherwise severe personal injury may result If no water flows valve is inoperative Shut down the boiler until a new relief valve has been installed 2 After following the above war...

Страница 21: ...ted with water 3 hoses A water circulation pump 2 flush valves if not installed Note Before flushing the heat exchanger additional flush valves A and B must be installed on the near boiler piping incl...

Страница 22: ...and allow the solution to circulate through the boiler Refer to the manufacturer s literature for information about the circulation time 10 Rinse the cleaning solution from the boiler a Remove the fre...

Страница 23: ...Temperatures on page 10 Check for cross piping between the cold and hot water lines The water from the hot water faucet is too hot Is the set temperature set too high Check the boiler s temperature s...

Страница 24: ...an motor Manual RESET E110 Abnormal air pressure Manual RESET E205 Abnormal operation heating supply thermistor Auto RESET E218 Abnormal operation heating return thermistor Auto RESET E278 Abnormal op...

Страница 25: ...peration Pre Heat Aquastat Alarm E762 Abnormal flue gas duct Vent pipe not properly inserted Auto RESET E773 Using the wrong gas Parameter RESET E777 Abnormal operation LWCO limit external device Auto...

Страница 26: ...eriod replacement of the Product or components may be authorized by Navien only Navien does not authorize any person or company to assume for it any obligation or liability in connection with the repl...

Страница 27: ...ncluding but not limited to installation in violation of applicable rules laws or building codes inadequate water quality condensate damage improper venting incorrect gas type water pressure absence o...

Страница 28: ......

Страница 29: ...er When you contact Technical Support please have the following information at hand Model number Serial number Date purchased Installation location and type Error code if any appears on the front pane...

Отзывы: