56 NFC Service Manual
Version 1.0
4.12.5 Flame Rod Assembly
Part
Check Point
Function
Continuously discharges a high voltage spark to the main burner until gas ignites.
Failure Event
1. Unable to ignite during the ignition process.
2. Produces multiple unsuccessful attempts to ignite.
Effects
1. The unit cannot ignite during the ignition process and “E003” or “E004” error codes will display.
2. Durability of the igniter wears down
Error Code
E003, E004, E012
Diagnostic
Visual inspection: Check wire connections are secure.
Testing/inspection
information
BLACK: 0~10 uA
Igniter
Flame Rod
Ignite gap distance : 3.5~4.5mm (1/8”)