12
13
www.vexve.com
4.1.
DN 32
Locking groove No. 1
Hole saw Ø 30 mm
Main pipeline: nominal size
A
B
C
DN 40
85
+2
-0
20
93
DN 50
87
+0
-10
20
93
DN 65
89
+0
-10
20
93
DN 80
90
+0
-10
20
93
DN 100
91
+0
-10
20
93
DN 125
91
+0
-10
20
93
DN 150
92
+0
-10
20
93
DN 200
92
+0
-10
20
93
DN 300
92
+0
-10
20
93
DN 400
92
+0
-10
20
93
DN ≥500
93
+0
-10
20
93
Speed: 285 RPM
Area 2
Scale C1
When drilling through a DN 40 pipe, feeding must be stopped
10 mm before the maximum feeding distance, and when drilling
through a DN 50 pipe, it must be stopped 15 mm before the
maximum feeding distance. With other pipe sizes, the maximum
feeding distance can be used.
The “A” dimensions are valid for Lenox and Sandvik hole saws.
Содержание DN 25
Страница 1: ...Instructions for Naval hot tapping equipment and valves...
Страница 6: ...6 www vexve com 2 1 Exploded view...
Страница 22: ...22 www vexve com...
Страница 23: ...23 www vexve com...