9
PEAK HOLD MODE OPERATION
Red LED
Approached Target Torque
Buzzer
(((((((( )))))))) ((((((( )))))))
Reach Target Torque
Current Torque Value
(Peak Hold)
START
Apply Torque
((…((… …))…)) ((…((… …)) …))
Buzzer
Green LED
Reach 80% of Target Torque
Flashing
Apply Torque
Released
Setting Target Torque
Reach 80% of Target Torque
Recording
*Note 2
*Note 1
(System initial)
*Note 3
*Note 4
Note:
1.
If
is displayed, that means this wrench has ever been
applied more than 110% of torque of the spec.
2.
If
is displayed, that means the wrench’s memory is
full and the next value record can not be written in. Please refer
the “Peak Hold Mode Recorded Value Review” section to clear
the momory records.
3.
When 80% of the target torque is reached, the green LED will
begin to flash and the alarm tone will beep intermittently.
4.
When the target torque is approached, the alarm will change to a
steady tone and the green LED will stop flashing and stay on.
The red LED will also illuminate.