5. When the recovered weight reaches the pre-set recovery weight, recovery is completed, and 

you can manually end system recovery by pressing§, and the alarm will stop. At this point 

the LCD screen will display the gross weight of the refrigerant container. 

� 

�110 

Controller 

1tJ 

�110 

Scale 

J  ' 

Lb 

nr, 

uo.c 

oz 

Note: 

During the recover input entering process, if there is an input error needed to be re-entered, you 

only need to press the shift button 

G, 

to move the flashing figure to the position of the figure to be 

corrected and re-enter the amount to correct the recovery weight. 

When turning on the scale, the default is in charging and the default is Oat start-up, press again to 

display "recover" and amount of the last recovery will be displayed. You can then change to the 

required amount to be removed from the system. 

Warning: 

The  recovered  refrigerant  volume  cannot  exceed 

80% 

of  the  total  capacity  of  the  refrigerant 

container. Over-filling recovery vessels is extremely dangerous! 

2.7. Bluetooth Synchronization Setup 

If the handheld keypad or scale needs to be changed, you will need to synchronize the Bluetooth 

connection as follows: 

1. On the SCALE press and hold 1 second

to turn on only the scale, then the sync light will 

flash. 

2. With the handheld keypad OFF, press in§,8,(ID.�. � sequence, then the handhold 

device enters sync program, the LCD will show•• • and the alarm will buzz. The sync will be 

done within 1 minute, and the LCD will display 

bf[, 

the alarm will buzz for 2 seconds. It will save 

the new MAC address and the handheld keypad will tum off automatically. 

Note: 

If the sync is not done within  1 minute, the handhold device is still out of sync. It 

will 

keep the 

previous 

MAC 

address, and the handheld device turns off automatically. 

If 

synchronization fails 

three consecutive times, please call for technical support. 

2.8. Instruction 

If the scale needs to be calibrated due to inaccuracy caused by severe impact, please return to 

NAVAC or an authorized distributor for repair. 

08 

Making Your Job More Enjoyable 

A

VA.C 

Maintenance 

1. Only use a moist cloth and a small amount of cleaning fluid when cleaning the surface of the 

scale. Avoid using chemical solvents to wipe the product. 

2. If repair is required, contact a NAVAC dealer company. Once the device is opened by an 

individual or non-authorized company, we will no longer provide warranty. 

3. After finishing usage, promptly turn off the scale. When left idle for long-periods, promptly 

remove the battery. 

4. Do not store the scale in moist, high-temperature or magnetized locations. 

Accessory list 

1. Scale (scale plate and hand held device) 

2. User manual 

3. 1.5V AA alkaline battery 

4. 1.5V AAA alkaline battery 

5.Bag 


09 

Содержание NRS2i01

Страница 1: ...5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 2: ...ipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radionvtechnician for help CONTENT Product introduction Function parameters Product description Operating instructions 3 Maintenance 9 Accessory list 9 Making Your Job More Enjoyable J 7l VA C Product introduction NRS2i01 is a wireless sm...

Страница 3: ...n Numeric button 3 and Back light On Off button Automatically close after 30 seconds by default 4 Combo button Numeric button 4 and Clear button 5 Combo button Numeric button 5 and Recover button 6 0 Numeric button 6 7 0 Numeric button 7 8 0 Numeric button 8 9 II Combo button Numeric button 9 and Power On Off button 10 0 Numeric button 0 11 B Shift button 12 Combo button Enter and Exit button 13 r...

Страница 4: ...roller n Scale u Lb nn u u 2 3 Back light setting You can turn on off the back light based on different conditions The default setting is no light Press the button in order to switch on the light and press it again to switch it off The light stays 04 MakingYour Job More Enjoyable A VA C onfor 30 seconds After 30 seconds the light will turnoff automatically if the scale isnot in use 2 4 Clear setti...

Страница 5: ... allows users to rapidly and safely recover refrigerant from the system After entering Recover mode input the recover value to start recovery process The recovery volume must be at least1 8 oz 1 Switch on the scale 2 Place the refrigerantcontainer onthe scale and wait until the readingstabilizes displaying the total weight of the container For example if the total weight ofthe container is29 lbs 1...

Страница 6: ... sync light will flash 2 Withthe handheld keypad OFF press in 8 ID sequence then the handhold device enters sync program theLCD will show and the alarm will buzz The sync will be done within 1 minute andthe LCD will displaybf the alarm will buzz for 2 seconds It will save the new MAC address and the handheld keypad willtum offautomatically Note If the sync is not done within 1 minute the handhold ...

Отзывы: