background image

Making Your Job More Enjoyable 

J\

7l.

VA.C 

Dear customer: 
We are very happy that you have  decided to  purchase one of the  all new  NAVAC series of 
products. 

In order to correctly use this product, please carefully read this instruction manual in full prior to 

use, especially the Notes and Warnings. 

Note 

The manufacturer is not responsible for any radio or TV interference caused by unauthorized 
modifications to this equipment. Such modifications could void the user authority to operate the 

equipment. 

Note 

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant  to  Part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses and can radiate radio frequency energy and, if not installed and used in accordance with 
the instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be 
determined  by turning  the  equipment  off and on,  the user is encouraged  to try to correct  the 
interference by one or more of the following measures: 

-Reorient or relocate the receiving antenna. 
-Increase the separation between the equipment and receiver. 
-Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

-Consult the dealer or an experienced radionv technician for help. 

CONTENT 

Product introduction  •·· •······································································ 
Function parameters •········································································· 
Product description  •·· •······································································ 
Operating instructions  ••• ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••  3
Maintenance  •·· •···············································································  9 

Accessory list ••• •••••••••••••••••••• ••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••  9

Making Your Job More Enjoyable 

J\

7l.

VA.C 

Product introduction 

NRS2i01 is a wireless smart e-Scale that is supported by NAVAC's advanced technology and all 

new design concepts. Its primary use is for installation and maintenance of HVAC systems, to set 
exact  refrigerant  weights  for charging systems,  and  when recovering  refrigerant  from  existing 
systems,  and  issue  warning  alerts  when  finished.  It  is  approved  and  has  FCC,  IC  and  RED 
certifications. 

The  product  was  designed  primarily  from  the  perspective  of  the  service  technician.  It  is  a 
magnesium alloy cast scale plate design, and the storage bag makes it light and easy for users to 
carry. The hand-held scale keypad design makes it easy for users to both retrieve and store. The 
internal storage compartment for remote keypad inside the scale provides better protection and a 
longer life for the keypad device. 

Functional parameters 

Model 

NRS2i01 

Maximum weight 

220Lb 

Resolution 

0.2oz 

Accuracy 

0.05% 

Power source 

4xAA, 4xAAA 

Work environment 

14~104  °F 

Scale dimensions 

8.25x10.2 

Weight 

3.3 lbs 

Wireless broadcast distance 

32.8 feet, it recommended that normal weighing 
within 16.4 feet, function operation within 9.8 feet 

Product description 

1. Diagram

Scale 

Platform 

Storage 

Compartment 

Scale Keypad 

01 

Содержание NRS2i01

Страница 1: ...5 Commonwealth Ave Woburn MA 01801 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 2: ...ipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radionvtechnician for help CONTENT Product introduction Function parameters Product description Operating instructions 3 Maintenance 9 Accessory list 9 Making Your Job More Enjoyable J 7l VA C Product introduction NRS2i01 is a wireless sm...

Страница 3: ...n Numeric button 3 and Back light On Off button Automatically close after 30 seconds by default 4 Combo button Numeric button 4 and Clear button 5 Combo button Numeric button 5 and Recover button 6 0 Numeric button 6 7 0 Numeric button 7 8 0 Numeric button 8 9 II Combo button Numeric button 9 and Power On Off button 10 0 Numeric button 0 11 B Shift button 12 Combo button Enter and Exit button 13 r...

Страница 4: ...roller n Scale u Lb nn u u 2 3 Back light setting You can turn on off the back light based on different conditions The default setting is no light Press the button in order to switch on the light and press it again to switch it off The light stays 04 MakingYour Job More Enjoyable A VA C onfor 30 seconds After 30 seconds the light will turnoff automatically if the scale isnot in use 2 4 Clear setti...

Страница 5: ... allows users to rapidly and safely recover refrigerant from the system After entering Recover mode input the recover value to start recovery process The recovery volume must be at least1 8 oz 1 Switch on the scale 2 Place the refrigerantcontainer onthe scale and wait until the readingstabilizes displaying the total weight of the container For example if the total weight ofthe container is29 lbs 1...

Страница 6: ... sync light will flash 2 Withthe handheld keypad OFF press in 8 ID sequence then the handhold device enters sync program theLCD will show and the alarm will buzz The sync will be done within 1 minute andthe LCD will displaybf the alarm will buzz for 2 seconds It will save the new MAC address and the handheld keypad willtum offautomatically Note If the sync is not done within 1 minute the handhold ...

Отзывы: