![Nautilus U618 Скачать руководство пользователя страница 10](http://html2.mh-extra.com/html/nautilus/u618/u618_service-manual_3553271010.webp)
10
Console Service Mode – x618 series Consoles
The Console Setup Mode lets you input the date and time, set the units of measurement to either English or Metric,
change the machine type, control the sound settings ( on/ off), or see maintenance statistics (Total Run Hours – for
service technician use only).
1. To go into the Console Setup Mode:
- For the later version of the console, hold down the PAUSE/END button and Increase (
) button together for 3 sec-
onds while in the Power-Up Mode.
- For the earlier version of the console, hold down the PAUSE/END button and Left button together for 3 seconds
while in the Power-Up Mode.
Note:
Push PAUSE/END to exit the Console Setup Mode and return to the Power-Up Mode screen.
2. The Console display shows the Date prompt with the current setting. To change, push the Increase/Decrease buttons
to adjust the currently active value (flashing). Push the Left/Right buttons to change which segment is the currently
active value (month / day / year).
3. Push OK to set.
4. The Console display shows the Time prompt with the current setting. Push the Increase/Decrease buttons to adjust
the currently active value (flashing). Push the Left/Right buttons to change which segment is the currently active value
(hour / minute / AM or PM).
5. Push OK to set.
6. The Console display shows the Units prompt with the current setting. To change, push OK to start the Units option.
Push the Increase/Decrease buttons to change between “MILES” (Imperial English units) and “KM” (metric units).
Note:
If the units change when there is data in User Statistics, the statistics convert to the new units.
7. Push OK to set.
8. The Console display shows the Sound Settings prompt with the current setting. Push the Increase/Decrease buttons
to change between “ON” and “OFF”.
9. Push OK to set.
10. The Console display shows the TOTAL RUN HOURS for the machine.
To go to the next Console Setup Mode prompt, push the OK button.
To enter the Manufacturing Menu (MFG Menu):
- For the later version of the console, hold down the PAUSE/END button and Increase (
) button together for 3 sec-
onds while in the Power-Up Mode.
- For the earlier version of the console, hold down the PAUSE/END button and Left button together for 3 seconds
while in the Power-Up Mode.
The Console display shows the Firmware Version string. Push the Up/Down buttons to move through the MFG Menu
options. Push OK to make a selection.
a. ENTER MFG TEST – This option is intended for use on the manufacturing production line only. It is a chained
series of tests similar to the tests listed below, but optimized to be run on the production line. This chained test
should not be used anywhere but on the production line.
b. DEBUG TERMINAL – Not used.
c. MOVE LIFT – (E618 elliptical only) Used to adjust a new lift motor. The Console displays “UP MX DN MN RT
CAL”: Up arrow will move the lift motor to the maximum position; Down arrow will move the lift motor to the
minimum position; Right arrow will perform a lift motor calibration by moving the lift motor to its minimum and
maximum position. Note: Lift motor calibration is no longer required, so calibration is not needed.
d. RESET MFG NVM – Resets MFG NVM (non volatile memory). Must be run before lift motor calibration if a valid
lift table exists in NVM (lift motor has been calibrated before).
e. RUN BEEP TEST – Sounds each system beep / tone / sequence in order. Press any key to exit
f. RUN BUTTON TEST – The Console display shows the function of each button as buttons are pressed. If the
display shows an incorrect function, the overlay on the Console may be incorrect for that model. If the display
does not show a function, the firmware version may be incorrect. No beeps are sounded during this test.
To exit the test, push and hold one of the long key sequences (i.e. long Pause / End + Right or long Pause / End +
Down).