23
TROUBLE SHOOTING
F831806-014-01 M-7100E 10005
SYMPTOM CAUSE
SOLUTION
Console display
doesn’t illuminate
A).No power to treadmill.
B).Console wire is not fully
connected.
C).Overload, over current
breaker has been tripped.
D).Console power source
damaged
A). Insure the on-off switch is on. If switch indicator
light isn’t illuminated, insure AC power cord is fully
inserted in receptacle and breaker is not tripped.
B).
Remove console (reverse assembly starting at
step 3.3) Inspect to insure wiring harness plugs
are fully connected and that all pins are fully
inserted into plugs.
C).
Check breaker (near on/off switch). Push
breaker in to reset. If power is restored, deck/belt
maintenance may be required.
D).Turn off power, open the motor cover, turn on
the power The power pilot lamp (LED2) on the
interface PCB should be illuminated. If not, contact
customer service.
Display not
completely
illuminated
A).Console damaged.
B).Console source power
unstable.
A).Replace the console PCB.
B).Check power, turn off power then open the
motor cover, turn on the power and check the
console power pilot lamp(LED2 on the interface
PCB. should be illuminated, if not, contact
customer service
LS is displayed
A).RPM sensor problem.
B).Driver system problem.
A).Turn off power, wait 15 seconds then turn on
again, press start. If motor works and LS is still
shown,
turn off power,
open the motor cover,
insure the sensor wire is connected correctly or
replace it if defective. If motor does not work,
proceed to step B.
B).
Turn off power, open the motor cover and
replace the interface PCB. If motor still doesn’t
start, replace inverter.
Show E1
Memory device damaged.
Replace console PCB.
Show E2
Console can not receive the
incline motor signal or signal
error.
1. Reset power by unplugging machine from
wall, wait 30 seconds and plug back into wall.
If incline motor works, remove motor cover
and inspect to insure wiring harness plugs are
fully connected and that all pins are fully
inserted into plugs
2. If wires check ok but still show E2, replace the
incline motor VR.
3. Reset power, if incline still does not work,
check that the incline operation pilot lamps
LED4(UP) & LED5(DOWN) illuminates when
operate the incline function is activated, if not
light, check console wire or replace interface
PCB.
If lights illuminate correctly – Contact
Customer Service
Show LUBRICATE
DECK
Belt/Deck Maintenance
required
Perform deck / belt maintenance per previous
instructions.
Show E3
OTC
short circuit over 5
seconds.
1. Wipe sweat off the OTC to prevent bad
connections.
2. Check to insure connection wire isn’t broken
.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.