Engineer Manual-Trouble Shooting
VERSION
C
2.18.
Error message『Err1』:Inverter no output after start.
Show Err1
Reset power
OFF
ON
Does the console show
『UArt』
after 10 seconds?
Yes
Refer to 2.13. error
message
『UArt』
No
Press START to quick start.
Motor did not move then show
Err1?
Yes
Replace inverter to newest version
(refer to 1.3.) and update the console
firmware version to the newest
version.(great than V1.05)
No
Set incline to level 15 then set to
level 0.
Does the incline work abnormal
and stop then show
Err1?
Yes
No
System operating normal but please check
the inverter shall be the new version
and console firmware version great
than V1.05, if not, replace or update
it.
The incline motor jammed or input power too low, the input
power shall over 90V(110V system)/200V(220V system).
After to
eliminate incline motor jammed and input power
problem, please check the inverter shall be the new
version (refer to 1.3.) and console firmware version
great than V1.05, if not, replace or update it.