CLEAN CHEMICAL FEED FILTER & FOOT VALVE:
(If so equipped)
Part of the optional Auto Fill & Chemical Feed system, the Filter & Foot Valve is on the end of the chemical
feed hose that is placed in the chemical jug as part of the chemical feed system. Regularly examine the filter
and clean as needed.
To test the Foot Valve:
•
Remove the Filter & Foot Valve from the end of the chemical feed hose and rinse in fresh water.
•
Blow through the valve from the filter side of the barb.
o
If the Foot Valve is functioning, air should move freely from the filter side, but will not flow from
the barb side of the filter.
o
If valve is not functional, clean or replace as needed.
Heavy chemical build-up can be removed with a mild acid rinse and/or the use of a brush and compressed
air.
CLEAN VACUUM SHUTOFF ASSEMBLY SCREEN:
Inside the recovery tank, on top of the stand pipe, is the Vacuum Shutoff Assembly. It functions to prevent
debris and water from being sucked into the vacuum motors. Operating the MX500HE without the Vacuum
Shutoff Assembly or with a poorly maintained assembly will greatly decrease the life of the vacuum motors
and will void the warranty.
If debris builds up on this filter, it will reduce the vacuum air flow and may cause a significant decrease in the
rate of water recovery. If debris prevents the float from moving or seating against the Filter Cap Assembly, it
may not stop the airflow when the tank fill with water, and the water will be sucked into the vacuums and
blown out the exhaust.
Use defoamer to prevent foam or moisture from entering vacuums (See Page 16).
To clean:
•
Do not pull up on top of cap.
Carefully pull up from the bottom of filter cap assembly to pull the
assembly off of the stand pipe. Then pull float off of riser pipe.
•
Pull fibers and lint off and rinse filter cap assembly and float with clean water.
•
Place the float back on the riser pipe then push the filter cap assembly back onto the stand pipe and
replace the recovery tank lid.
Flow Direction
Flow Direction
Vacuum Shutoff
Assembly
Filter & Foot Valve
PDE100-11P
Chemical Feed Hose
Filter Cap Assembly
Vacuum Shutoff Float
Содержание HYDRO-FORCE MX500HE
Страница 1: ...1 LMANN13 Revised 02 16 2018 Nautilus MX500HE Operating Manual...
Страница 36: ...36 Parts Replacementpartsavailableforrepairof yourMX500HE Section 3 KIT A PT054 KIT B PT055 KIT C PT056...
Страница 39: ...39 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740...
Страница 40: ...40 Pump Out Pump AP37F PARTS ASSEMBLY...
Страница 41: ...41 2 4 4 6 7 10 39 12 3 11 3 5 1 8 9 8 9 8 9 2 8 9...
Страница 45: ...45 48 49 49 47 47 47A 47A 47 47A 51 51 37 9 54 64 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS 47 47A...
Страница 46: ...46 44 67 117 PUMP BOTTOM VIEW OF BASE 68 112 60 60 3 59 37 39 61 62 57 56 9 54 9 54 63 55 3 59 61 62 120...
Страница 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK...
Страница 50: ...50 96 91 97 9 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 117 117...
Страница 51: ...51 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 117 9 97...
Страница 52: ...52 HEATER PARTS 42 42A 98 114 110 71 113 114...