30
FLUSH SOLUTION TANK AND PUMP: (continued from previous page)
•
Disconnect the solution hose and tool.
•
Use the 4’ short section of vacuum hose to vacuum the remaining acid solution out of the solution
tank.
•
Pour two or three gallons of clean water into the solution tank.
•
Connect the pump prime hose to the solution outlet female quick connect.
•
Direct the end of the prime hose into the recovery tank vacuum barb.
•
Turn one or both of the vacuums ON and turn the solution pump ON. Let the pump run until most
of the water has been pumped out of the solution tank.
Do not let the pump run dry. Turn the pump OFF before the water gets to the
bottom of the tank.
•
Turn the vacuums OFF and disconnect the prime hose.
•
Place a bucket under the drain valve and open the drain valve to drain the water out of the recovery
tank.
•
Close the drain valve and dispose of the water.
CLEAN PUMP INLET FILTER
A restricted Pump Inlet Filter can prevent the solution pump from providing adequate pressure for cleaning.
A restriction or air leak on the pump inlet hose can
also damage the solution pump check valves and
plunger seals.
•
To examine the filter, open the solution tank
lid on the front of the machine. The filter is in
the bottom of the solution tank.
•
Grasp the filter cap and unscrew the filter
from the brass nipple by turning counter-
clockwise. Clean or replace the filter as needed
(PP14-806504).
Before proceeding with this
procedure, drain the solution tank & recovery tank. Make sure both power cords are disconnected.
•
To examine the pump inlet hose, release the latches on the front/bottom of the machine and tilt the
tanks off of the base assembly.
•
Examine the hose for kinks, clogs or holes and repair or replace the hose as needed.
(Replacement Hose: NM5086 – sold per foot)
•
Tilt the tanks back onto the base and secure the latches.
Inside View: MX3-200H Solution Tank
Vacuum acid solution out of
Solution Tank
SOLUTION FILTER
PP14-806504
Содержание Hydro-Force MX3-200H
Страница 1: ...1 LMANN09 Revised 01 29 2015 Nautilus MX3 200H Operating Manual ...
Страница 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Страница 38: ...38 Optional Pump Out Pump AP37 PARTS ASSEMBLY ...
Страница 39: ...39 1 2 6 7 8 9 11 3 8 9 12 4 4 3 10 5 15A 8 9 8 9 39 2 ...
Страница 43: ...43 48 49 49 47 47 47A 47 47 47A 47A 51 51 37 9 54 64 52 VACUUM MOUNTS CONNECTIONS 9 54 64 ...
Страница 48: ...48 96 91 97 9 94 105 OPTIONAL PUMP OUT CONNECTIONS 99 95 93 118 118 ...
Страница 49: ...49 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 9 97 118 39 ...
Страница 50: ...50 HEATER PARTS 111 113 114 112 2 115 2 116 2 42 42A 98 111 ...