![background image](http://html1.mh-extra.com/html/nautilus/extreme-mxe-200/extreme-mxe-200_operating-manual_711729009.webp)
9
Operation Procedures
Knowledge of the proper operation of the MXE-200 is required to ensure
user safety and efficient performance of the extractor.
SET UP AND OPERATION
1. Electrical Cords:
Two 25’ power cords are supplied with the Nautilus Extreme MXE-200. Cord #1 powers vacuum #1, the
Solution Pump and the cooling fan; Cord #2 powers vacuum #2 and the waste pump if so equipped. The
amperage required by each cord requires that the two cords be plugged into separate circuits:
•
Cord #1 (Left side) will supply power to Vacuum #1, the Solution Pump & Cooling Fan.
•
Cord #2 (Right side) will supply power to the Vacuum #2 and Pump-out Pump.
This machine is able to run when both cords are connected to separate 15amp circuits. If other electrical
equipment is connected to the circuit during operation; 20amp circuits may be required.
20amp circuits are
usually found in kitchens and bathrooms.
An overloaded circuit will not always trip the circuit breaker
immediately, but may not provide sufficient voltage for proper operation and the breaker may trip eventually.
Plug the two power cords into two outlets from different circuits. If the Dual Circuit Indicator green light
fails to light, you may be on the same circuit and may need to select a different plug for one of the cords. If
the Dual Circuit Indicator green light comes on, you are plugged into two different circuits. Proceed with
your set-up procedure.
(Dual Circuit Indicator light may take up to 30 seconds to recognize the two circuits and turn ON.)
If a circuit breaker trips or the pump circuit breaker trips during operation, reset the breakers and move the
cord to another outlet as needed.
Power Cord – AX32
25’ – 12 gauge M-F Plugs
Cord #1
Cord #2
Dual Circuit Indicator Light
Содержание Extreme MXE-200
Страница 1: ...1 LMANN08 Revised 01 29 2015 Nautilus MXE 200 Operating Manual EXTREME ...
Страница 23: ...23 M1200 Wiring Diagram Nautilus MXE 200 Wiring Diagram Cord 1 ...
Страница 37: ...37 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740 ...
Страница 38: ...38 Pump Out Pump PARTS ASSEMBLY ...
Страница 39: ...39 1 4 4 6 7 8 9 10 11 3 3 8 9 12 8 9 39 8 9 2 2 5 ...
Страница 47: ...47 85 86 87 101 86 102 1 VACUUM SHUTOFF ASSEMBLY INSIDE RECOVERY TANK WITHOUT OPTIONAL PUMP OUT 85 87 111 ...
Страница 49: ...49 92 91 95 94 112 13 14 14A 104 105 1 39 PUMP OUT CONNECTIONS ...
Страница 50: ...50 35 36 36A 78 36 36A 34 39 127 128 129 2 1 130 32 34 119 39 131 ...