35
TROUBLESHOOTINg
Condition/Problem
Things to Check
Solution
No display/partial display/
unit will not turn on
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
of unit
Connection should be secure and undamaged. Replace adapter
or connection at unit if either are damaged.
Check data cable integrity
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or otherwise
damaged. Replace Console if damaged.
Console Display
If Console only has partial display and all connections are fine,
replace the Console.
If the above steps do not resolve the problem, contact Customer
Care for further assistance.
Unit operates but Contact
HR not displayed
HR cable connection at
Console
Be sure cable is connected securely to Console.
HR cable box connection
Be sure cables from handlebars and cable to Console are secure
and undamaged.
Sensor grip
Be sure hands are centered on HR sensors. Hands must be kept
still with relatively equal pressure applied to each side.
Dry or calloused hands
Sensors may have difficulty with dried out or calloused hands.
A conductive electrode cream such as “Signa Crème” or “Buh-
Bump” can help make better conduct. These are available on the
web or at medical or some larger fitness stores.
Static Handlebar
If tests reveal no other issues, Static Handlebar should be re-
placed.
Unit operates but Telemet-
ric HR not displayed
Chest Strap (optional)
Strap should be “POLAR
®
” compatible and uncoded. Make sure
strap is directly against skin and contact area is wet.
Interference
Try moving unit away from sources of interference (TV, Micro-
wave, etc).
Replace Chest Strap
If interference is eliminated and HR does not function, replace
strap.
Replace Console
If HR still does not function, replace Console.
Console displays “E2” error
code
Check data cable integrity
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly. Small
latch on connector should line up and snap into place.
Console Electronics
If tests reveal no other issues, Console should be replaced.
Содержание E514c
Страница 1: ...ASSEMBLY MANUAL OWNER S MANUAL Manual en Español Latino Americano http www nautilus com E514c ...
Страница 10: ...10 4 Attach Console Mast to Frame Assembly NOTICE Do not crimp Console Cable 6 mm Q P B C X6 ...
Страница 13: ...13 8 Attach Legs to Frame Assembly A 11 10 O D L X2 ...
Страница 14: ...14 9 Attach Lower Handlebar Arms X2 L 14 15 D O A 19 N X2 ...
Страница 16: ...16 11 Attach Upper Handlebar Arms 13 X8 6 mm G 12 B C ...
Страница 38: ...Nautilus Bowflex Schwinn Fitness Universal 8001054 111512 B EN ...