29
C
ARE AND
M
AINTENANCE
•
Soak the housing system in fresh water after each salt water use, during which all control
buttons/knobs should be operated a few times to avoid the accumulation of salt residue;
wipe the housing with a towel before opening.
•
Carefully press the housing lock safety button for a few times to avoid the accumulation
of salt residue.
•
After each day of diving, it is advisable to have the main O-ring in the front part of the
housing removed from its groove with the O-ring remover and inspected for damage. Also
check that the O-ring retains its original circular shape; never stretch the O-ring excessively
or remove it with a sharp object. The O-ring groove should be cleaned to ensure it is free
from any salt deposit or foreign material; lightly coat the O-ring with the provided
lubricant before reinstalling it in the groove. A damaged O-ring should be discarded
immediately and replaced only with one that is provided by NAUTICAM.
•
Replace the main O-ring annually. It is recommended that you ship the housing to our
distributor for a complete overhaul every year or after every 200 dives.
Содержание NA-G9
Страница 1: ...1 ...
Страница 25: ...Connect 25 4 Turn the port locking lever to the release position as shown 5 Lift housing cap ...
Страница 33: ...33 ...