background image

10 

 

1.

 

Install  the  CR2032  battery  provided 
into  the  battery  compartment  on 
the  circuit  board  inside  the  front 
part of the housing.  

 

5.

 

Setting up the moisture alarm: 
 

 

 

 

 

2.

 

Switch the alarm on. The LED light will 
flash  blue  once  and  turn  blue  for  five 
seconds  indicating  the  battery  is 
normal.  Then it  goes  into  flashing  blue 
light standby mode.  

 

3.

 

Test  the  alarm  by  connecting  the  two 
wires  near  the  bottom  of  the  housing 
with  a  damp  cotton  bud;  the  alarm 
should  start  giving  out  a  repeating 
“beep” sound along with a flashing red 
light.    The  “beep”  sound  and  the  light 
should  keep  on  going  for  5  seconds 
after  the  removal  of  the  damp  cotton 
bud . 

 

Содержание Atomos shogun

Страница 1: ...0...

Страница 2: ...hrough the innovative designs of our products We strive to achieve a high level of user friendliness by allowing stress free installation and easy operation of all important functions of the camera Ea...

Страница 3: ...To return your product for service please contact your regional authorized service centre s Please note that this warranty only applies when the product is purchased in the territory where the service...

Страница 4: ...ction manual 4 Hand pump 5 Spare silicone rubber main o ring 6 O ring remover 7 CR2032 battery Vacuum Check and Leak Detection System 8 Lubricant 9 Set of Allen keys Spare silicone rubber o ring Lubri...

Страница 5: ...e the housing as this may lead to a pressure difference between the atmosphere and inside the housing 6 Care must be taken when opening the housing as pressure may build up inside the housing which in...

Страница 6: ...cations 6 Identification of Parts 7 Opening and Locking the Housing 8 Preparation of the Housing 9 Installing the Monitor 13 Connecting to the Camera Housing 14 Care and Maintenance 16 Optional Access...

Страница 7: ...sistant polycarbonate Dimensions Width 286mm Height 176mm Depth 120mm Weight Approx 2 35kg Buoyancy Positive Depth rating 60 metres Operating Temperature Normal operating temperature is between 10 C a...

Страница 8: ...aded holes for monitor hood 4x 13 Monitor on off button 5 REC button 14 Housing lock safety button 6 PLAY button 15 Housing lock 7 1 4 threaded holes attachment points 4x 16 Waveform Monitoring button...

Страница 9: ...k anti clockwise for 270 until the lock reaches the Open position as shown 3 Close the housing while the housing lock is in the Open position 4 Turn the housing lock clockwise for 270 until the lock r...

Страница 10: ...of the housing is free from any foreign material the groove can be cleaned with the aid of a microfiber cloth 3 Place the main O ring into the groove first at the corners then the whole perimeter 4 Se...

Страница 11: ...once and turn blue for five seconds indicating the battery is normal Then it goes into flashing blue light standby mode 3 Test the alarm by connecting the two wires near the bottom of the housing with...

Страница 12: ...ertain amount of temperature variation it is recommended to conduct the vacuum test in an environment where the temperature is stable 4 After the target vacuum level is reached i e steady green light...

Страница 13: ...up LED indicator Status Flashing Blue light Standby mode The moisture alarm is active and the system is ready for vacuum indication whenever a vacuum is detected Flashing Red light with beeping sound...

Страница 14: ...urn the three locking levers in the direction as shown 3 Secure the monitor by turning the three locking levers towards the monitor as shown 2 Connect the HDMI cable with L connector to the monitor 4...

Страница 15: ...dard HDMI bulkhead ii Insert the HDMI bulkhead with cable into the hole and tighten the it with a spanner iii Connect the HDMI cable to the camera s HDMI connector i Unscrew the M16 plug from the thre...

Страница 16: ...ousing to HDMI bulkhead i Unscrew the cap off the HDMI bulkhead ii Unscrew the cap off the HDMI cable iii Align and plug the HDMI cable in the HDMI bulkhead Tighten the connection by turning the threa...

Страница 17: ...its groove with the O ring remover and inspected for damage Also check that the O ring retains its original circular shape never stretch the O ring excessively or remove it with a sharp object The O...

Страница 18: ...r Nauticam Atomos Shogun housing P N 17951 Nauticam Atomos Shogun housing mounting system P N 17952 Nauticam Atomos Shogun housing mounting adaptor for NA A7S P N 17953 Nauticam Atomos Shogun housing...

Страница 19: ...18 P N 17954 Tripod plate for NA A7S and NA GH4...

Страница 20: ...19...

Отзывы: