Vacuum valve system

remove the plug of M16 accessory 

port from the housing

remove the cap from the vacuum 

valve

slightly lubricate the o-ring and 

make sure the o-ring is in place

then tighten the vacuum valve to 

the housing with the tool provided

connect hand pump to the valve 

and pump several times until it 

reaches the target vacuum level 

close vacuum valve cap

It is recommended to leave the housing 

for at least 20mins to ensure it is sealed. 

If the LED light changes from steady 

green light to rapidly 

fl

 ashing yellow light, 

that means there is a leakage. Please 

check every O-ring and then conduct the 

vacuum test again.

hand pump

moisture alarm 

window

accesory port

on housing

vacuum valve

1

2

Moisture alarm window colour indication :

Steady Blue

Flashing Blue

Steady Green

Steady Red

Flashing Yellow

Flashing Red

Alternating 

Blue and Red

device is turned on
standby mode,

ready for pumpng

target vacuum level

is reached

out of battery

vacuum level

is dropping

vacuum is totally lost,

circuit stalled untill 

device is switched off

vacuum is totally lost,

circuit stalled untill 

device is switched off

* drawings as illustrations only

OPTIONAL ACCESSORIES

Содержание 17226

Страница 1: ...DSLR Introduction 2 2 3 4 7 8 Package Contents Important Instructions Part Names and Functions Housing Mount Opening the housing PN 17226 9 Closing the housing 10 16 Preparation for Use Optional Acce...

Страница 2: ...tems listed below before using this product If some items are missing or damaged contact your local Nauticam dealer After purchase we suggest that you reuse all packaging materials for future travelli...

Страница 3: ...are supervised and or given instruction by a responsible person concerning use of the product to ensure that they can use it safely Do not seal the housing when travelling by air as this may lead to a...

Страница 4: ...ONS Delete button Menu button WB button QUAL button Metering button Fn 3 button i button Live view selector Multi selector Moisture alarm window 1 2 3 4 5 7 9 6 8 10 Rear View 1 2 3 4 5 7 6 10 A Multi...

Страница 5: ...ex mark M16 Accessory port Main switch M16 Accessory port Port locking lever Lens release button Optical fiber cable connection M10 Accessory port Main command dial Mode dial lock release button M14 A...

Страница 6: ...F ON lever ISO lever LV lever PV lever Fn 2 lever 1 4 Threaded tripod holes Zoom Focus knob Playback lever Movie record lever Sub command dial Shutter release lever AF mode lever Zinc Anodes Fn 1 leve...

Страница 7: ...mounting ball HDMI D C cable in 190mm length Universal tripod plate Mounting ball set for tripod legs 26074 26075 25221 25224 M14 Nikonos 5 pin bulkhead M14 Ikelite style bulkhead M10 Strobe mounting...

Страница 8: ...8 OPENING THE HOUSING depress housing unlock button turn housing lock outward lift up the back housing drawings as illustrations only 1 2 3...

Страница 9: ...ate the main O ring make sure nothing is caught between front and back housing and that they are fully aligned before locking turn housing lock inward until you hear and feel it click into place housi...

Страница 10: ...in place and make sure it is engaged with lens gear attach the camera tray by tightening the tray screw into the tripod socket of the camera make sure the camera buttons are engaged with the camera t...

Страница 11: ...rt Mounting depress safety button and rotate anti clockwise lubricant the port O ring before mounting align index mark push port assembly straight in rotate locking lever clockwise to lock 1 2 3 drawi...

Страница 12: ...ing an O ring remover clean the O ring groove with a cloth and ensure that it is free from salt or other foreign materials lightly coat it with provided lubricant return the main O ring by slowly pres...

Страница 13: ...re alarm window will flash in BLUE when it is working correctly test the alarm connect the wires with a dampened cotton bud the alarm will give a repeating beep and the mositure alarm window will flas...

Страница 14: ...shoe test the flash trigger by pressing the shutter release button on the camera the LEDs under optical bulkheads should flash instantaneously positive terminal should be facing up This housing uses a...

Страница 15: ...on to release pressure before unlocking port lock If using without vacuum valve please follow from step 2 unlock port lock and remove port assembly press the blue button to reset vacuum alarm before r...

Страница 16: ...m steady green light to rapidly flashing yellow light that means there is a leakage Please check every O ring and then conduct the vacuum test again hand pump moisture alarm window accesory port on ho...

Страница 17: ...e the anti corrosion screw screw the M10 strobe mounting ball onto the housing as shown the anti corrosion screw may also be unscrewed while removing M5 screw if this is happening you can seperate the...

Страница 18: ...not travel with camera inside housing Operate all controls and buttons at least 3 times while immersed in fresh water We recommand cleaning and inspecting the main O ring each time after diving for an...

Страница 19: ...d service center s Please note that this warranty only applies when the product is pur chased in the territory where the service center is lo cated NAUTICAM accepts no liability for any damage to and...

Страница 20: ...90x220mm Carbon Fibre Aluminium Float Arm Buoyancy 720g 72233 Single Bayonet Holder II for 70 Float Arm 72244 Double Bayonet Holder II for 90 Float Arm 72234 Double Bayonet Holder II for 70 Float Arm...

Страница 21: ...Optional wet lens accessories 25101 M67 flip diopter holder for M67 macro ports 87512 Shade for 130 Objective Lens 25108 M67 Double Flip Holder for M67 Macro Ports 87518 Strobe Mounting Brackets for...

Страница 22: ...Nauticam Internationl Ltd Rm 2203 CCT Telecom Bldg 11 Wo Shing St Fo Tan Hong Kong Tel 852 26902711 Fax 852 26909778 URL www nauticam com Gallery www nauticam smugmug com...

Отзывы: