NV5LT/NV3.5LT TROUBLESHOOTING MANUAL
RESPONDING TO ALARMS
VERSION 3.3 2016-03-10
PAGE 4.1.3
Electrostatic Protection
The transmitter's assemblies contain semiconductor devices that are susceptible to damage from
electrostatic discharge. The following precautions must be observed when handling an assembly which
contains these devices.
Electrical Discharging of Personnel
Personnel should be electrically discharged by a suitable grounding system (e.g., anti-static mats,
grounding straps) when removing an assembly from the transmitter, and while handling the assembly
for maintenance procedures.
Handling/Storage
An assembly should be placed in an anti-static bag when it is not installed in a host transmitter, or
when it is not undergoing maintenance. Electronic components should be stored in anti-static
materials.
Tools/Test Equipment
Testing and maintenance equipment – including soldering and unsoldering tools – should be suitable
(i.e., grounded tip) for contact with static sensitive semiconductor devices.
Stress Current Protection
Every precaution should be taken to ensure the static sensitive semiconductor devices are protected
from unnecessary stress current. This is achieved by ensuring that current is not flowing when an
electrical connection is broken, and that voltages are not present on external control/monitoring circuits
when they are connected.
CAUTION!
Electrostatic energy is produced when two insulating materials are
rubbed together. A person wearing rubber-soled shoes, walking across a nylon
carpet or a waxed floor, can generate an extremely large electrostatic charge. This
effect is magnified during periods of low humidity. Semiconductor devices such as
integrated circuits, field-effect transistors, thyristors and Schottky diodes may be
damaged by this high voltage unless adequate precautions are taken.
Содержание NV3.5LT
Страница 2: ......
Страница 4: ......
Страница 8: ...NV5LT NV3 5LT TROUBLESHOOTING MANUAL PAGE 4 VIII VERSION 3 3 2016 03 10 ...
Страница 256: ...NV5LT NV3 5LT TROUBLESHOOTING MANUAL WIRING CONNECTOR LISTS PAGE 4 3 14 VERSION 3 3 2016 03 10 ...
Страница 262: ...NV5LT NV3 5LT TROUBLESHOOTING MANUAL READING ELECTRICAL SCHEMATICS PAGE 4 4 6 VERSION 3 3 2016 03 10 ...
Страница 294: ...VERSION 3 3 2016 03 10 SD 32 Figure SD 32 NAFP109B Output Power Probe and Sample PWBs ...
Страница 307: ...VERSION 3 3 2016 03 10 MD 8 Figure MD 8 NAPA31C Power Amplifier PWB Q1 ...
Страница 316: ...VERSION 3 3 2016 03 10 MD 17 Figure MD 17 NAL14 1 Input Reject Load Assembly L2 1 INPUT REJECT PWB TOP VIEW END VIEW ...
Страница 322: ...NV5LT NV3 5LT TROUBLESHOOTING MANUAL LIST OF TERMS PAGE 4 6 2 VERSION 3 3 2016 03 10 ...
Страница 323: ......