10 000 WATT FM BROADCAST TRANSMITTER
FM10
Page 5-26
01 October 2002
NOTE
If one of the six-way splitter's cables has open or
short circuited, the associated RF power module's
switching power supply will be inhibited due to low
RF drive input level and the
MODULE RF DRIVE
and
associated
PA VDC FAIL PWR SPLY
lamp shall be
on.
(c)
If the transmitter has not been latched off,
verify the voltage on U33-7 of the control/
monitor PWB is near that recorded as
IPA
Refld Pwr Level
in table 5-6.
5.11.10.2 IPA Forward Power:
Determine whether
an excessive IPA forward power level caused the
alarm as follows:
(a)
If the
IPA SWR
alarm is on and the transmitter
has not been latched off, check cables between
the IPA combiner/splitter probe's output and
the RF power module inputs.
(b)
If the
IPA SWR
alarm is on and the transmitter
has been latched off, check for an open or short
circuit on the cables between the six-way
combiner splitter and the RF power module
inputs.
NOTE
If one of the six-way combiner/splitter cables has
open or short circuited, the associated RF power
module's switching power supply will be inhibited
due to low RF drive input and the
MODULE RF
DRIVE
lamp and associated
PA VDC FAIL PWR SPLY
lamp shall be on.
(c)
If the cables in steps (a) and (b) are not short
circuited and the transmitter is still latched off,
check the low voltage power supply PWB as
detailed in this instruction manual.
5.11.11 IPA TEMP ALARM:
An
IPA TEMP
alarm
can occur if the temperature sensed within the IPA
module exceeds 73
°
C due to a failed IPA module fan
or a blockage in the normal air flow. The
transmitter's RF output should not be affected by this
alarm, nor should the IPA switching power supply be
inhibited or tripped off by its associated
PWR MDL
circuit breaker. Trouble shoot an IPA temperature
alarm as follows:
NOTE
Following each trouble shooting action taken on the
IPA TEMP
alarm, press the
ALARM RESET
switch. If
the alarm lamp turns off, the fault has been cleared.
If the alarm lamp remains on, trouble shooting
should continue.
(a)
Check fan fuse F2 on the low voltage power
supply PWB (A26A1) by measuring the voltage
across it. An open fuse will cause the IPA module's
fan to turn off. If a fuse has become open circuit,
replace it and monitor for recurrence.
Since the IPA is not inhibited during an
IPA TEMP
alarm, the temperature of the IPA module may be
in excess of 73
°°
C. Use extreme care when
inspecting its air path and cooling fan.
(b)
Perform a visual inspection of the IPA module
for fan blockage. Check for air flow out of the
front of the module. If a blockage exists, it will
be necessary to remove the IPA module and
clean the obstructed air path or replace the fan,
as required. Verify 24 VDC is on P4-1
(normally mates with J4 of the IPA module) to
isolate a possible wiring defect.
NOTE
The IPA module may be temporarily replaced by an
RF power module while the IPA module is being
serviced. Refer to paragraph 5.8 to replace the IPA
module with an operational RF power module.
(c)
Once the IPA module has been removed,
measure the resistance of temperature sensing
thermistor RT1, located on top of the module.
If the IPA module has sufficiently cooled
(25
°
C), the resistance should be near 200K
ohms.
(d)
If the resistance measured in step (c) is near the
value specified, the control/monitor PWB's IPA
module temperature circuitry may be defective.
Содержание FM10
Страница 41: ...10 000 WATT FM BROADCAST TRANSMITTER FM10 Page 2 15 01 October 2002 Figure 2 1 External Input Output Interface...
Страница 99: ...10 000 WATT FM BROADCAST TRANSMITTER FM10 Page 5 30 01 October 2002 Figure 5 2 Tuning Shelf Installation...
Страница 125: ...10 000 WATT FM BROADCAST TRANSMITTER FM10 Page 8 5 15 November 1999 This Page Intentionally Left Blank...
Страница 161: ...10 000 WATT FM BROADCAST TRANSMITTER FM10 Page 9 13 15 November 1999 This Page Intentionally Left Blank...
Страница 173: ...Figure SD 1 Electrical Schematic FM10 FM Broadcast Transmitter Overview Page SD 1 15 July 1997...
Страница 174: ...Figure SD 2 Electrical Schematic AC DC Power Supply Sheet 1 of 2 Page SD 2 15 July 1997...
Страница 175: ...Figure SD 3 Electrical Schematic AC DC Power Supply Sheet 2 of 2 Page SD 3 15 July 1997...
Страница 176: ...Figure SD 4 Electrical Schematic Low Voltage Power Supply PWB NAPS09C 01 Page SD 4 15 November 1999...
Страница 177: ...Figure SD 5 Electrical Schematic 3 Phase Monitor PWB NAPC60 03 Page SD 5 15 July 1997...
Страница 178: ...Figure SD 6 Electrical Schematic RF Power Stage Sheet 1 of 2 Page SD 6 15 July 1997...
Страница 179: ...Figure SD 7 Electrical Schematic RF Power Stage Sheet 2 of 2 Page SD 7 15 July 1997...
Страница 180: ...Figure SD 8 Electrical Schematic RF Combiner Final Filter NAF79 Page SD 8 15 July 1997...
Страница 181: ...Figure SD 9 Electrical Schematic Control Monitor Function Page SD 9 15 July 1997...
Страница 182: ...Figure SD 10 Electrical Schematic Control Display PWB NAPD05 01A Page SD 10 15 July 1997...
Страница 185: ...Figure MD 1 Assembly Detail FM10 FM Broadcast Transmitter Front View Page MD 1 15 July 1997...
Страница 186: ...Figure MD 2 Assembly Detail FM10 FM Broadcast Transmitter Rear View Page MD 2 15 July 1997...
Страница 187: ...Figure MD 3 Assembly Detail NASR92 02 and 03 AC Power Supply Assemblies Page MD 3 15 November 1999...
Страница 188: ...igure MD 4 Assembly Detail 3 Phase Rectifier Assembly 182 7150 and 182 7150 01 Page MD 4 15 July 1997...
Страница 189: ...Figure MD 5 Assembly Detail NAG02 01 NAG02 02 Circuit Breaker Panel Page MD 5 15 July 1997...
Страница 190: ...Figure MD 6 Assembly Detail NAC76 Power Supply Control Panel Page MD 6 15 July 1997...
Страница 191: ...F Figure MD 7 Assembly Detail NAC66 01A or NAC66 03 Control Monitor Panel Page MD 7 5 November 1999...
Страница 192: ...Figure MD 8 Assembly Detail NAPD05 01A Control Display PWB Page MD 8 15 July 1997...
Страница 193: ...Figure MD 9 Assembly Detail NAI07 Intermediate RF Drive Splitter Page MD 9 15 July 1997...
Страница 194: ...Figure MD 10 Assembly Detail NAFP68 IPA Input Power Probe Page MD 10 15 July 1997...
Страница 195: ...Figure MD 11 Assembly Detail NAF79 RF Combiner Filter and NAFP64 RF Power Probe Page MD 11 15 July 1997...
Страница 196: ...Figure MD 12A Assembly Detail NAS43 02 Low Voltage Power Supply Page MD 12A 15 July 1997...
Страница 197: ...Figure MD 12B Assembly Detail NAS43 02A Low Voltage Power Supply Page MD 12B 15 July 1997...
Страница 198: ...Figure MD 13 Assembly Detail NAPS09C 01 Low Voltage Power Supply PWB Page MD 13 15 November 1999...
Страница 199: ...Figure MD 14 Assembly Detail NAPC60 03 3 Phase Monitor PWB age MD 14 15 July 1997...
Страница 200: ...Figure MD 15 Dimensional Information FM10 10 000 Watt FM Broadcast Transmitter Page MD 15 15 July 1997...