User Manual - Stand-Up Lift: EASYLEV 5 Range

Manufactured by NAUSICAA Médical S.A.S. / Approved by Ghizlane Labrosse (Biomedical Engineer)

• Article 1 : NAUSICAA Médical S.A.S. warrants this product against any defects in manufac-

turing and assembly of mechanical and electronic components. This warranty is for devices 

used only in accordance with NAUSICAA Médical S.A.S. terms of use.

The warranty covers all mechanical and electrical parts, except battery and breakage.

This warranty whose terms of use are defined below is valid for 60 months from the date of 

first departure from NAUSICAA Médical S.A.S.

• Article 2 : The warranty entitles the free labor and the free replacement of defective parts.

• Article 3 : The original out-going shipping costs of the device and all associated costs are 

the responsibility of the distributor. The goods always travel at the risk and the responsibility 

of the distributor.

Under warranty : return costs after intervention will be borne by NAUSICAA Médical S.A.S.

Out of warranty: return costs are at the expense of the distributor whether or not he accepts 

the repair estimate.

• Article 4 : The warranty does not apply if the claims are consecutive to:

- accident, misuse or neglect of the unit by the end customer.

- shipping performed without adequate protection.

- alteration or transformation not validated by NAUSICAA Médical S.A.S.

- the impact of external elements (natural disaster, fire, shock, humidity, flood, lightning, ...).

- installation and/or use in a non-compliant way with technical standards and safety (in 

case the unit would work in a country other than the country of origin) ; and/or if the electri-

cal power is not suited for the operating voltage of the device.

- a lack of routine maintenance.

• Article 5 : The distributor may not invoke the benefit of the warranty:

- if the device serial number has been removed, altered or rendered illegible.

- if the device under warranty has been modified without the approval of NAUSICAA Médical 

S.A.S.

• Article 6 : During the repair of any defective equipment, no loan will be made.

• Article 7 : All warranty claims must be exercised through the distributor.

• Article 8 : Sending spare parts under warranty will be made after consultation with the 

distributor customer service.

• Article 9 : Defective parts changed under or out of warranty will be guaranteed for 6 months 

from the date of repair or sending of the spare parts.

• Article 10 : No distributor can unilaterally change the terms of this warranty.

Warranty

Содержание EASYLEV 5 Series

Страница 1: ...MEDICAL DEVICE CONFORM TO STANDARD NF EN ISO 10535 2007 NAUSICAA Medical is certified ISO 13485 www nausicaa medical eu User Manual Stand Up Lift EASYLEV 5 Range Manufactured by NAUSICAA M dical S A...

Страница 2: ...eling General Safety Guidelines Technicals Dimensionals Characteristics EASYLEV5 EASYLEV5 with mechanical opening legs EASYLEV5 PLUS with electrical opening legs Technicals Dimensionals Characteristic...

Страница 3: ...ir a toilet or a wheelchair to be transferred while being active 1 The stand up lift has already been inspected at the factory to ensure that it is free from defects and that nothing is missing Nevert...

Страница 4: ...deformation on the hooks WARNING To preserve the inserts do not overtighten Assembly is done with the brakes locked Assembling Instructions EASYLEV5 Step 1 Take the device out of the box The device i...

Страница 5: ...no wear or deformation on the hooks Assembling Instructions EASYLEV5 with mechanical opening legs EASYLEV5 PLUS with electrical opening legs Step 1 Take the device out of the box The device is ready f...

Страница 6: ...the parking lever pointing upwards Castor Released When locking the castors always insure that both castors are locked If only one castor is locked on a sloping floor the unlocked wheel will roll down...

Страница 7: ...tonicity patients How to properly use a stand up lift 1 Low tonicity patients shall be transferred in a semi seated position Instructions for Use Your stand is designed to lift people so do not use it...

Страница 8: ...stand up lift 2 Medium tonicity patients shall be transferred in a standing position Likewise the patient s shins must be in contact with the shin block at all times In all cases the caregiver must b...

Страница 9: ...tatus of the control box and the battery Check that the actuator is properly secured Check that the battery is charged Stand up Lifts Use 7 Control Box 2 Functions Control Box 4 Functions User Manual...

Страница 10: ...rned are EASYLEV5 EASYLEV5 with me chanical opening legs The products concerned are EASYLEV5 EASYLEV5 with mechanical opening legs The products concerned are EASYLEV5 Plus with electrical opening legs...

Страница 11: ...oo much Standing up for PATIENT WITH CHEST TONICITY INSTRUCTIONS FOR USE Position the bottom of the backrest in the lumbar region in order that the ears of the attachment system are on either side of...

Страница 12: ...ty An assessment of the patient capacity is required before using a stand up lift and more precisely to make sure that the patient can bear weight on at least one leg and has sufficient tonicity in th...

Страница 13: ...66 51 50 47 Web www nausicaa medical com 12 All e du Piot ZA P le Actif 30660 Gallargues le Montueux FRANCE Tel 33 4 66 51 50 80 Fax 33 4 66 51 50 47 Web www nausicaa medical com 12 All e du Piot ZA...

Страница 14: ...ANCE A POORL Y MAINTAINED BATTERY DETERIORATES SAFETY INSTRUCTIONS BEFORE EACH USE Verify the presence and conditions of safety devices all axis and their constrained fixations pins clips and bolts an...

Страница 15: ...Labelling 13 For all models of the EASYLEV 5 Range User Manual Stand Up Lift EASYLEV 5 Range Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 3 4 2 1 5 7 8...

Страница 16: ...ensure through adequate measures and instructions that mechanical stress of the charging cord through bending tension shear crushing is excluded during loading or cleaning of the part This also applie...

Страница 17: ...675 Maximum height Low handles Position 1 1475 Position 2 1500 Position 3 1525 Handles high Position 1 1500 Position 2 1520 Position 3 1545 Low handles Position 1 1490 Position 2 1515 Position 3 1540...

Страница 18: ...eight 455 420 4 distance from the device to the maximum range 565 530 5 rounding diameter 900 1105 1 total length 840 995 9 total width closed feet 1210 1260 1 Maximum charge 180kg 180kg 18 Total weig...

Страница 19: ...9 cm Electronic protection when overloaded Protections types T l commande IP56 Remote control IP54 Control box IP65 Battery pack IP65 Actuator IP55 Stop limit switch Box in ABS Handcontrol with spiral...

Страница 20: ...s le v rin va s arr ter et une enclume s affichera Il sera alors poursuivre le fonctionnement de l appareil ompl te e toutes les charges incompl tes de la batterie inf rieures fre correspond au nombr...

Страница 21: ...steam use with a microfiber mop Do not direct steam directly on the electrical boxes MONTHLY MAINTENANCE Check that the device does not present any visible damages Check that no part is missing Check...

Страница 22: ...rt check Sling fixation hooks check State of the frame and of the painting check Additional checks for models with opening base legs Foot pedal or opening legs actuator check Spreaded legs system chec...

Страница 23: ...vot of wheels Sub patellar support slide ECP Pedal or Cylinder Assembly Foot Spacer System Assemblies of the right and left feet on Embase 8 Periodic lubrication Use a 3 in 1 product or similar Period...

Страница 24: ...t runner ECP Pedal or Cylinder Assembly Foot Spacer System Assemblies of the right and left feet on Embase 8 22 Periodic lubrication Use a 3 in 1 product or similar EASYLEV5 PLUS with electrical openi...

Страница 25: ...ION SLING FOR EASYLEV 5 ESL5 STR PF 13 FRONT AND SIDE WHEELS FOR EASYLEV AND WAYUP 5 WITH FIXED BASE WP5 RJND50 PF 14 REAR WHEELS FOR EASYLEV AND WAYUP 5 WITH FIXED BASE WP5 RJNFRD100 PF 15 3000N LIFT...

Страница 26: ...F 7 RIGHT FOOT FOR EASYLEV AND WAYUP 5 WP5 EP PD PF 8 LEFT FOOT FOR EASYLEV AND WAYUP 5 WP5 EP PG PF 9 REMOVABLE PLATFORM FOR EASYLEV AND WAYUP 5 WP5 EP PLA PF 10 HEEL BLOCK FOR RANGE 5 WP5 CLT PF 11...

Страница 27: ...ECP EMB PF 8 RIGHT FOOT FOR EASYLEV AND WAYUP 5 WP5 EP PD PF 9 LEFT FOOT FOR EASYLEV AND WAYUP 5 WP5 EP PG PF 10 REMOVABLE PLATFORM FOR EASYLEV AND WAYUP 5 WP5 EP PLA PF 11 HEEL BLOCK FOR RANGE 5 WP5...

Страница 28: ...OULEUR DE CORDON SECTEUR UMEC VB 26 User Manual Stand Up Lift EASYLEV 5 Range Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 2 2 7 2 6 2 8 2 4 2 5 2 3 2 9 1 3...

Страница 29: ...LEUR DE CORDON SECTEUR UMEC VB 27 User Manual Stand Up Lift EASYLEV 5 Range Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 2 1 2 7 2 6 2 8 2 4 2 5 2 3 2 9 2 1...

Страница 30: ...X III 28 User Manual Stand Up Lift EASYLEV 5 Range Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 2 1 5 3 4 NUMBER DESIGNATION REFERENCE 1 2 FUNCTIONS REMOTE...

Страница 31: ...Stand Up Lift EASYLEV 5 Range Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer 5 4 1 2 3 6 NUMBER DESIGNATION REFERENCE 0 COMPLETE CONTINUED EMERGENCY LOWERING...

Страница 32: ...CHAPE D EMBASE DE VERIN D ECARTEMENT DES PIEDS 3000N GRIS VS VRN ECP3 CEMB 3 CORDON SPIRALE POUR VERIN D ECARTEMENT DES PIEDS 3000N GRIS VSVRN ECP3 CRD Opening Legs Jack 3 000 Newtons NUMBER DESIGNATI...

Страница 33: ...The batteries are discharged or worn out Charge the device or change the batteries The weight lifted by the device is too important a weight symbol is displayed on the screen Decrease the weight lift...

Страница 34: ...32 User Manual Stand Up Lift EASYLEV 5 Range Manufactured by NAUSICAA M dical S A S Approved by Ghizlane Labrosse Biomedical Engineer...

Страница 35: ...does not apply if the claims are consecutive to accident misuse or neglect of the unit by the end customer shipping performed without adequate protection alteration or transformation not validated by...