WilTec GmbH is not responsible for detrimental effects and damage caused by an excessively
high outlet pressure of the booster pump on the water softener.
•
If the main water supply is interrupted, the main valve of the supply line should be closed im-
mediately or the bypass valve of the water softener should be switched to the bypass station to
prevent the water softener from being damaged by the negative pressure in the pipework
caused by the municipal water supply.
•
When the main water supply is restored, a large number of pollutants in the water pipe contam-
inate the treatment device. Therefore, first switch the bypass valve of the treatment device to
the bypass station, open the tap in the house, and drain the water from the dirty water supply
station.
•
The water softener must not be tilted or laid on its side during transport, installation or use.
•
The floor on which the water treatment device is installed should be level and have a load-
bearing capacity of more than 300
kg
⁄
m
. In addition, an AC power supply, a water inlet and outlet
interface, a waste water pipe, and a floor drain should be available.
•
Installation area:
o
SOFT-V1: 380 × 550 × 690
mm (L×W×H)
o
SOFT-V2: 380 × 550 × 1150
mm (L×W×H)
•
Do not install the softener near acidic and alkaline substances or near gases to avoid corrosion
on the softener.
•
The water softener must be installed indoors. Measures must be taken to insulate the housing
and pipework, in particular to protect against frost and solar radiation and for sealing.
•
It is forbidden to install the softener on a water pipe with a water pressure of more than 4.5
bar.
If the water inlet pressure exceeds 4.5
bar, a pressure-reducing valve must be installed (to be
purchased separately), otherwise the company accepts no responsibility for consequences
such as impairment or damage to the water softener due to excessive water inlet pressure and
any resulting damage.
•
The water softener should be installed and used in a room with a floor drain and smooth drain-
age. If the drain pipe or floor drain is blocked and the drain pump cannot drain normally due to
a power failure or other malfunction, please close the building’s main water inlet valve immedi-
ately. At the installation site, it must be ensured that objects in the neighbouring area or in the
part of the building below are not damaged or flooded if water escapes from the water softener
or the connection pipe.
•
As shown in the illustration below, the drain pipe and the overflow pipe must be secured with
ring clamps to prevent leakage during water drainage.
Fig.
1
Fig.
2
•
Before connecting the water supply pipe, remove any dirt and dust remaining in the pipe. Then
close the main valve before connecting the system.
•
The overflow and drain pipe must be provided with a free pipe guide. The length of the pipe may
not be increased and the pipe diameter may not be reduced without authorisation.
•
For the pipe connection, the pipe should be as close to the wall as possible, the pipe should run
straight, and the angles should be free. After installation, the pipe should be fixed to the wall
with a ring clamp. Pay attention to the height and placement angle of the pipe when it is con-
nected. There should be no obvious stresses after connecting the pipe to avoid water pipe
bursts and water leakage from the treatment device or pipework due to stresses in the pipework
during long-term use.
•
It is forbidden to combine the overflow and drain pipes in one pipe and insert it into the waste-
water outlet.