background image

If you should ever have a problem or question refer to this manual or call your dealer. If your dealer does not have the information 

you need, request they contact Nature’s Comfort and we will further educate them to provide the best possible customer service. If 

you are unable to get service from or reach your dealer you may contact Nature’s Comfort via email: 

[email protected]

. If you do not have email you may call 877-251-7740. Please keep in mind that Nature’s Comfort 

has no control over the installation, weather conditions, the efficiency of a building’s insulation or what is burned in a boiler.

 

How It Works 

 

The SM-H60 is a solar water heater that uses the sun’s radiant energy to heat water through the use of 60 double 

wall vacuum insulated glass tubes. Each tri-element glass tube has a coating on the outside of the inner layer of glass 

made up of nitrogen aluminum to absorb heat on top of a copper coating to transfer and hold in the heat. As water 

is heated through the glass it rises and flows into the boiler it is connected to, drawing in cooler water from the 

bottom of the boiler to circulate by thermo-siphoning. The double wall vacuum insulated glass tubes provide the 

best insulation and won’t freeze the water inside during winter nights. Heat production can reach up to 72,000 btu’s 

per day.

 

Safety Notes 

 

Always wear gloves and safety glasses whenever installing or working on or around the system. 

 

Tubes without water in them can reach over 400 degrees inside. 

DO NOT LOOK INTO OR PLACE YOUR FINGERS IN A 

TUBE OR MANIFOLD.

 

 

CAUTION! Water temperatures can exceed 200F! See additional notes on page 4

 

Placement of the Solar Heater 

 

Ensure frame is placed level in all directions. The top of the solar manifold must be within 2-4 feet of the side of 

boiler and must be lower than where it enters the water jacket on the solar return port so the heated water can rise. 

Use a 1” pex line from the top of the manifold to run on a straight upward angle to the solar return port on the 

boiler so the heated water will rise (thermo-siphoning) and so air cannot get trapped. It is designed to work most 

efficiently at that distance and is not guaranteed to work in any other way. 

 

The silicon ring gaskets for sealing the tubes to the manifold are not designed for pressures greater than 14 psi.  

Placing the bottom of the solar heater lower than 32 feet below the top of the boiler water jacket will damage the 

system. 

 

The SM-H60 is designed solely for installation and operation on the ground in conjunction with an outdoor boiler or 

insulated storage tank. Installing per this manual requires no pumps or controllers to work all on its own which 

provides many benefits. 

Assembly - 

Wear gloves and safety glasses!

 

 

Assemble the frame and mount the manifold. See drawings on pages 6, 7 & 8. 

 

ONLY INSTALL THE GLASS TUBES AND FILL WITH WATER BEFORE OR AFTER DAYLIGHT. Doing so at any other time 

will cause the glass tubes to shatter due the extreme temperature difference of the glass tubes reaching over 400 

degrees being hit with unheated water. Heat is still produced on cloudy days! 

The other option is to have water 

continually running in from the bottom of the manifold and install the tubes from the bottom up so they will fill with 

water immediately upon insertion into the manifold.

 

Keep the glass tubes inside the shipping boxes completely 

covered from daylight until ready to immediately install.

 

 

Before inserting a glass tube into the manifold, coat the end with soapy water before and after putting the black 

rubber trim ring on and also coat the manifold gasket for ease of installation. Carefully install each tube into the 

Содержание SM-H60

Страница 1: ...s Comfort LLC You must read this entire instruction manual before beginning installation to completely understand system requirements Aquastats heat exchangers mixing valves pex pipe pumps valves and 1 brass pex fittings are all available from your Nature s Comfort Dealer or you may order directly by calling 877 251 7740 ext 304 ...

Страница 2: ...f the solar manifold must be within 2 4 feet of the side of boiler and must be lower than where it enters the water jacket on the solar return port so the heated water can rise Use a 1 pex line from the top of the manifold to run on a straight upward angle to the solar return port on the boiler so the heated water will rise thermo siphoning and so air cannot get trapped It is designed to work most...

Страница 3: ...of the water jacket drain outlet at a downward angle from the boiler to the bottom of the solar manifold so the cooler water can fall Use a T so you can still drain the water jacket if needed Install a 1 line from the top of the manifold on a straight upward angle to an extra port on the boiler so the heated water will rise thermo siphoning and so air cannot get trapped Installing on boilers with ...

Страница 4: ...fort is designed for this An aquastat must also be installed at the top of the manifold to turn the pump on at 130F and off at 125F This setup is not recommend as pump or electrical failure can lead to overheating and possibly push a glass tube out or burst a pex line that could drain the system It is always best to have the solar heater within 2 4 feet of the boiler Heat Exchangers Install a wate...

Страница 5: ...oint and shuts off when it falls to 5 degrees above the DHW set point so utility energy is not used to reverse heat the boiler See diagram later in this manual Lower the set point of your DHW to utilize your solar water heater as much as possible Make sure to bypass all other heat exchangers in the boiler line so all energy is used only for heating DHW All drawings and pictures are copyrighted mat...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Отзывы: